Número de pieza
					Desmilitarización
					Vigencia
					UOM
					NIIN
				 
				
			 
							
					
						Información de la pieza
						Three filtered functions
					 
				 
						
				
					NSN
				
				
					Número de acciones nacionales:
				
				
			 
			
				
					TXT
				
				
					Descripción:
				
				
					Radio Frequency Interfere Filter				
			 
			
				
				
					Código de nombre del artículo:
				
				
					00765				
			 
										
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						-55.0/+125.0 degrees celsius					
				 
							
					
						MRC:
						The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
					 
					
						Source Impedance Rating Per Function:
					
					
						50.0 ohms 1ST radio INTERFERENCE50.0 ohms 2ND radio INTERFERENCE50.0 ohms 3RD radio interference					
				 
							
					
						MRC:
						The total opposition per function,presented by a load to the output terminals of an item.AHAS
					 
					
						Load Impedance Per Function:
					
					
						50.0 ohms 1ST radio INTERFERENCE50.0 ohms 2ND radio INTERFERENCE50.0 ohms 3RD radio interference					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the power line alternating current.AHBB
					 
					
						Power Line Frequency Rating Per Function In Hertz:
					
					
						400.0 1ST radio INTERFERENCE400.0 2ND radio INTERFERENCE400.0 3RD radio interference					
				 
							
					
						MRC:
						The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
					 
					
						Operating Current Rating Per Function In Amps:
					
					
						30.0 1ST radio INTERFERENCE30.0 2ND radio INTERFERENCE30.0 3RD radio interference					
				 
							
					
						MRC:
						The greatest amount of voltage loss per function,resulting from the devices inherent opposition to the flow of electrical current.AHBE
					 
					
						Maximum Voltage Drop Per Function:
					
					
						2.5 volts ac 1ST radio interference and 6.0 volts dc 1ST radio INTERFERENCE2.5 volts ac 2ND radio interference and 6.0 volts dc 2ND radio INTERFERENCE2.5 volts ac 3RD radio interference and 6.0 volts dc 3RD radio interference					
				 
							
					
						MRC:
						Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
					 
					
						Principal Circuitry Type Per Function:
					
					
						Inductance-capacitance 1ST radio interference inductance-capacitance 2ND radio interference inductance-capacitance 3RD radio interference					
				 
							
					
						MRC:
						The maximum permissible temperature increase in the item as a result of its operation under normal conditions.AHCG
					 
					
						Maximum Tempurature Rise:
					
					
						40.0 degrees celsius					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Encased					
				 
							
					
						MRC:
						Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
					 
					
						Features Provided:
					
					
						Nut and washer					
				 
							
					
						MRC:
						Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
					 
					
						Functional Terminal Type And Quantity:
					
					
						3 threaded stud input 1ST FUNCTION3 threaded stud output 2ND function					
				 
							
					
						MRC:
						The maximum alternating current root mean square voltage that the insulating material/s/ of the item will withstand without resulting in disruptive discharge or deterioration.CQDZ
					 
					
						Maximum Dielectric Withstanding Ac Rms Voltage:
					
					
						500.0 volts at sea level					
				 
							
					
						MRC:
						The level of electrical potential and type of current,per function,for which the item is designed.CQGC
					 
					
						Operating Voltage Rating And Type Per Function:
					
					
						250.0 volts ac 1ST radio interference 1ST function and 600.0 volts dc 1ST radio interference 1ST FUNCTION250.0 volts ac 2ND radio interference 2ND function and 600.0 volts dc 2ND radio interference 2ND FUNCTION250.0 volts ac 3RD radio interference 3RD function and 600.0 volts dc 3RD radio interference 3RD function					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the body is fabricated.CQRG
					 
					
						Body Material:
					
					
						Metal					
				 
							
					
						MRC:
						The maximum direct current voltage that the insulating material/s/ of the item will withstand without resulting in disruptive discharge or deterioration.CRDC
					 
					
						Maximum Dielectric Withstanding Dc Voltage:
					
					
						1.2 kilovolts at sea level					
				 
							
					
						MRC:
						The metallic,nonmetallic,and/or chemical properties with which the body is plated,dipped and/or coated. the treatment is designed to protect the body surface/s/ and cannot be wiped off.CRST
					 
					
						Body Surface Treatment:
					
					
						Tin