						Número de pieza:
						370-117405-1					
 
					
					
					
					
				 
			 
						
				
					NSN
				
				
					Número de acciones nacionales:
				
				
			 
			
				
					TXT
				
				
					Descripción:
				
				
					Thermostatic Switch				
			 
			
				
				
					Código de nombre del artículo:
				
				
					00451				
			 
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						12.250 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						11.000 inches 					
				 
							
					
						MRC:
						Indicates the type of sensor or transducer used in the item to convert temperature changes to switch actuating force.AKBY
					 
					
						Tempurature Sensing Element Type:
					
					
						Internal sensor					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Clip					
				 
							
					
						MRC:
						An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.CQGB
					 
					
						Contact Action Stimulus:
					
					
						Increase					
				 
							
					
						MRC:
						The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
					 
					
						Nonpile-up Contact Arrangement:
					
					
						1 pole  single throw  normally closed  momentary action					
				 
							
					
						MRC:
						Indicates the type of terminal for providing electrical connection to the item.CSCF
					 
					
						Terminal Type:
					
					
						Wire lead					
				 
							
					
						MRC:
						The amount of current that the contacts are rated to make or break with a specified load.CTHF
					 
					
						Contact Load Current Rating:
					
					
						2.0 amperes resistive load first voltage					
				 
							
					
						MRC:
						The amount of current that the contacts are rated to make or break with a specified load.CTHF
					 
					
						Contact Load Current Rating:
					
					
						4.0 amperes resistive load second voltage					
				 
							
					
						MRC:
						The amount of current that the contacts are rated to make or break with a specified load.CTHF
					 
					
						Contact Load Current Rating:
					
					
						6.0 amperes resistive load fourth voltage					
				 
							
					
						MRC:
						The amount of current that the contacts are rated to make or break with a specified load.CTHF
					 
					
						Contact Load Current Rating:
					
					
						6.0 amperes resistive load third voltage					
				 
							
					
						MRC:
						The adjustability of the contact.CTYC
					 
					
						Contact Adjustability:
					
					
						Deactuation point not adjustable and  actuation point not adjustable					
				 
							
					
						MRC:
						The rating of the stimulus required to actuate and/or deactuate the contact(s).CTYX
					 
					
						Contact Stimulus Rating:
					
					
						44.00 actuation point  degrees fahrenheit and 54.00 actuation point  degrees fahrenheit and 35.00 deactuation point  degrees fahrenheit and 45.00 deactuation point  degrees fahrenheit and 9.00 differential point  degrees fahrenheit					
				 
							
					
						MRC:
						The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
					 
					
						Contact Voltage Rating In Volts:
					
					
						125.0 ac at sea level second voltage					
				 
							
					
						MRC:
						The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
					 
					
						Contact Voltage Rating In Volts:
					
					
						250.0 ac at sea level first voltage					
				 
							
					
						MRC:
						The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
					 
					
						Contact Voltage Rating In Volts:
					
					
						30.0 dc at sea level fourth voltage					
				 
							
					
						MRC:
						The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
					 
					
						Contact Voltage Rating In Volts:
					
					
						30.0 ac at sea level third voltage					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the alternating current.FREQ
					 
					
						Frequency In Hertz:
					
					
						60.0 first voltage					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the alternating current.FREQ
					 
					
						Frequency In Hertz:
					
					
						60.0 second voltage					
				 
							
					
						MRC:
						The type of media for which the item is designed.MEDA
					 
					
						Media For Which Designed:
					
					
						Gas					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
					 
					
						Style Designator:
					
					
						Cylindrical