Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
ws-c4948-s
Información de la pieza
48 ports wire speed 10/100/1000 base-t RJ-45 female 4 alternative ports can accommodate optional 1000BASE-X sfp optics image management port 10/100BASE-TX RJ-45 female dte indicators for fan PS1, PS2; power supply status green (operational) red (faulty) system status green and red image management port green (good) and orange (disabled/off, not connected) power supply input current 4.0 amps at 100.0 volts or 2.0 amps at 240.0 volts output current 25.0 amps at 12.0 volts dc ac power 300.0 watts weight of switch with power supply 16.5 pounds relative humidi type 10.0 to 90.0 percent noncondensing; includes fan tray
NSN
Número de acciones nacionales:
TXT
Descripción:
Electronic Switch
Código de nombre del artículo:
42816
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
17.290 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.712 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
16.140 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+32.0/+104.0 degrees fahrenheit
MRC:
The minimum and maximum temperatures at which an item can be stored without detrimental effect.AFJQ
Storage Tempurature Range:
-40.0/+167.0 degrees fahrenheit
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
2000.0 meters
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Partially enclosed
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Rack
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
100.0 single voltage and 240.0 single voltage
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Used for server switching