Número de pieza TYPEANUPM61

Range Indicator Calibrator

Precios y disponibilidad

Envíe este formulario para conocer los precios actuales y la disponibilidad de esta NSN.
Número de pieza:
Cantidad:
Dirección de correo electrónico:
Teléfono:
Referencia:
Compañía:
Nombre:

No compartimos ni vendemos su información a nadie.
Privacidad | Letra chica

All major credit cards accepted as well as gov. p-cards
Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
typeanupm61
Desmilitarización:
Yes - DEMIL/MLI
Vigencia:
Unidad de medida:
NIIN:
005649477

Información de la pieza
TO 33A1-10-14-4

NSN
Número de acciones nacionales:
6625-00-564-9477 6625005649477
TXT
Descripción:
Range Indicator Calibrator
INC
INC
Código de nombre del artículo:
00767
INC
COM
Conformidad:
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
115.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
1.0 kilohertz
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
50.0 hertz
MRC:
The name assigned to the item by the joint electronics type designation system.AKWA
Joint Electronics Type Designation System Item Name:
Range calibrator
MRC:
The type number assigned to the item by the joint electronics type designation system.AKWB
Joint Electronics Type Designation System Item Type Number:
TS-102B/AP
MRC:
The total opposition (resistive and reactive) which the item offers to the output flow of alternating current.ANSR
Output Impedance Rating:
50.0 ohms
MRC:
The output voltage rating at which the item is designed to operate.AQYB
Output Voltage Rating:
30.0 volts
MRC:
Indicates the location of the input pulse.BHXP
Err Default:
Err default
MRC:
Indicates the location of the input pulse.BHXP
Input Pulse Location:
Internal
MRC:
Indicates the type of polarity of the input pulse.BHXQ
Input Pulse Polarity Type:
Positive
MRC:
Indicates the type of output polarity of the item.BHXS
Err Default:
Err default
MRC:
Indicates the type of output polarity of the item.BHXS
Output Polarity Type:
Positive
MRC:
Indicates the type of marker provided with the item.BHXT
Err Default:
Err default
MRC:
Indicates the type of marker provided with the item.BHXT
Marker Type:
Range
MRC:
The range of complete cyclic changes,per unit of time,for which the marker pulse recurrence is rated.BHXW
Marker Pulse Recurrence Frequency Range:
Between 40.0 hertz and 4.0 kilohertz
MRC:
The number of alternating current phases.FAAZ
Phase:
Single