Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
ts147dup
Desmilitarización:
Yes - DEMIL/MLI
Unidad de medida:
No qup EA
NSN
Número de acciones nacionales:
TXT
Descripción:
Radar Test Set
Código de nombre del artículo:
03661
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
12.000 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
19.000 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
115.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 1600.0 hertz
MRC:
The principal parts that are included in an assembled unit.AEAS
Major Components:
Pick-up antenna rf cable assembly cord cord adapter connector adapter connector adapter instruction books
MRC:
The number of parts supplied with the item which may be required for application.AFHS
Accessory Component Quantity:
1 and 1 and 1 and 1 and 1 and 1 and 1 and 2
MRC:
The name of the government agency or commercial organization that controls the manufacture of the accessory item.AKVY
Accessory Controlling Agency:
Buaer usaf buships buaer usaf usaf usaf buships
MRC:
The specific number used to identify the accessory.AKVZ
Accessory Identifying Number:
AT-68/UP type no And CG-530 type no And CG-92A/U type no And CX-337/U type no And UG-446/U type no And UG-397/U type no And UG-273/U type no
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Single item w/carrying case
MRC:
Indicates the type of test for which the item is designed.AQXY
Test Type For Which Designed:
Alignment of beacon equipment and radar systems rf circuits measurement of power measurement of frequencys
MRC:
The testing functions such as range,sensitivity,output,and the like,for which the item is designed.AQXZ
Operating Test Capability:
Signal generator range 8500 mc to 9600 mc frequency meter range 8470 mc to 9630 mc rf power monitor and reference level indicator scale graduated in increments of 15 ua from 150 to 0 to 150 to be interpreted as increments of 0.05 mw from 2 to 0 to 2 mw
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
14.000 inches
MRC:
The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
Specification Or Standard:
No TS-147D/UP type