Número de pieza TRI-B6DC

Standardized Electronic Module

Precios y disponibilidad

Envíe este formulario para conocer los precios actuales y la disponibilidad de esta NSN.
Número de pieza:
Cantidad:
Dirección de correo electrónico:
Teléfono:
Referencia:
Compañía:
Nombre:

No compartimos ni vendemos su información a nadie.
Privacidad | Letra chica

All major credit cards accepted as well as gov. p-cards
Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
tri-b6dc
Desmilitarización:
Yes - DEMIL/MLI
Vigencia:
Unidad de medida:
NIIN:
014692350

Información de la pieza
Ul and ulc listed microcomputer chip technology dual input module designed to monitor 2 sets of dry contacts requiring 2 address settings using FPI-32 programmer/tester (nsn 6625014530407); relative humidity not to exceed 93 percent non-condensating; compatible with numerous pyrotronics detectors and addressable interfaces both intelligent and manual mounts into double gang switchbox 3.500 in Deep (not included) using standard blank double gang switch plate (not included) max Wire size recommended, 14 awg min 18 awg supervised switches max 27.0 vdc max Current 3.5 milliamps (during polling) and 10 ohms max Contact resistance max Circuit cable length is 200 ft (18 awg) end-of-line device is a 3.6K ohm 0.250 watt resistor p/n 140-820185

NSN
Número de acciones nacionales:
5963-01-469-2350 5963014692350
TXT
Descripción:
Standardized Electronic Module
INC
INC
Código de nombre del artículo:
36647
INC
COM
Conformidad:
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+32.0/+120.0 degrees fahrenheit
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Mechanical
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
Indicates the type of connection and its location on the item.BJBP
Connection Type And Location:
Terminal block w/screw rear
MRC:
Indicates the type and number of contact(s) included in the connection.BJBW
Connection Contact Type And Quantity:
8 terminal block w/screw external
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Ninterfaces and supervises normally open contacts (fire detection) or normally closed contacts (security detection) with the mxl system ald loop circuit ixl system icon loop circuit or XL3 system inx loop circuit