Número de pieza
					Desmilitarización
					Vigencia
					UOM
					NIIN
				 
				
					
						Número de pieza:
						tm10n06-3					
 
					
					
					
					
				 
			 
						
				
					NSN
				
				
					Número de acciones nacionales:
				
				
			 
			
				
					TXT
				
				
					Descripción:
				
				
					Thermal Relay				
			 
			
				
				
					Código de nombre del artículo:
				
				
					03883				
			 
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						2.375 inches 					
				 
							
					
						MRC:
						A measurement of the longest straight line across a circular cross-sectional plane.ADAV
					 
					
						Overall Diameter:
					
					
						0.797 inches 					
				 
							
					
						MRC:
						The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
					 
					
						Environmental Protection:
					
					
						Hermetic					
				 
							
					
						MRC:
						The designation that identifies the schematic diagram of the contact configuration.APFR
					 
					
						Contact Arrangement:
					
					
						Single pole  single throw  normally open					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						1 plug-in					
				 
							
					
						MRC:
						The highest voltage at which the contacts are rated for normal operating,expressed in volts.CYCS
					 
					
						Contact Maximum Voltage Rating In Volts:
					
					
						115.0 ac					
				 
							
					
						MRC:
						The highest current at which the contacts are rated for normal operation,expressed in amps.CYCT
					 
					
						Contact Maximum Current Rating In Amps:
					
					
						6.0 ac					
				 
							
					
						MRC:
						The amount of voltage for which the heater is designed,expressed in volts.CYCU
					 
					
						Heater Voltage Rating In Volts:
					
					
						6.3					
				 
							
					
						MRC:
						A numeric value indicating the elapsed time interval of the item,expressed in seconds.CYCW
					 
					
						Delay Time In Seconds:
					
					
						20.0 fixed operate 					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						7 pin