Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
NSN
Número de acciones nacionales:
TXT
Descripción:
Power Distribution Panel
Código de nombre del artículo:
02794
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
5.000 inches
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
19.375 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
13.375 inches
MRC:
The means of attaching the item.ADJH
Mounting Method:
Wall
MRC:
The name designation of the written or printed document.ALYQ
Document Title:
Listed in buships dwg no 9000-S6202-74203 rev a
MRC:
The element,compound,or mixture of which the panel is fabricated,excluding any surface treatment.ANJG
Panel Material:
Steel
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Three
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Watertight
MRC:
The number of complete cyclic changes,per unit of time,for which the output frequency is rated.ANSQ
Output Frequency Rating:
60 hertz
MRC:
The number of panels provided.APCA
Panel Quantity:
1
MRC:
The number of electrical inputs accommodated.APNW
Electrical Input Quantity:
1
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
450.0 ac pounds per hour wet
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
450.0 ac volts
MRC:
An indication of whether or not an input neutral is provided.APNY
Input Neutral:
Not provided
MRC:
The number of electrical outputs provided.APNZ
Electrical Output Quantity:
6
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
450.0 ac volts
MRC:
An indication of whether or not an output neutral is provided.APPC
Output Neutral:
Not provided
MRC:
The cycles per second /hertz/ of input alternating current.APPY
Input Frequency In Hertz:
60.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects a surface.SURF
Surface Treatment:
Enameled
MRC:
The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
Specification Or Standard:
D-20A type