Número de pieza
					Desmilitarización
					Vigencia
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Número de acciones nacionales:
				
				
			 
			
				
					TXT
				
				
					Descripción:
				
				
					Uninterruptible Power Supply				
			 
			
				
				
					Código de nombre del artículo:
				
				
					67374				
			 
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						18.240 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						3.500 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						17.000 inches 					
				 
							
					
						MRC:
						The number of batteries required for operation.AEXR
					 
					
						Battery Quantity:
					
					
						1					
				 
							
					
						MRC:
						The maximum altitude at which the item is rated to function.AKAE
					 
					
						Maximum Operating Altitude Rating:
					
					
						10000.0 feet					
				 
							
					
						MRC:
						The number of input alternating current phase(s).ANPM
					 
					
						Input Phase:
					
					
						Single single operating power rqmt					
				 
							
					
						MRC:
						The input value/s/,or range of values,for which the item is rated.APNX
					 
					
						Input Voltage Rating:
					
					
						120.0 ac pounds per hour wet single operating power rqmt					
				 
							
					
						MRC:
						The output value/s/,or range of values,for which the item is rated.APPA
					 
					
						Output Voltage Rating:
					
					
						120.0 ac volts  single power output					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
					 
					
						Input Frequency Rating:
					
					
						47.0 hertz  single operating power rqmt and 63.0 hertz  single operating power rqmt					
				 
							
					
						MRC:
						The number of complete cyclic changes,per unit of time,for which the output is rated.APTS
					 
					
						Output Frequency Rating:
					
					
						47.0 hertz  single power output and 63.0 hertz  single power output					
				 
							
					
						MRC:
						The ambient temperature range at which the item is designed to operate.AYNH
					 
					
						Operating Ambient Tempurature Range:
					
					
						+0.0/+40.0 degrees celsius					
				 
							
					
						MRC:
						The rated output power that an item can safely consume or provide,measured in watts.BGQR
					 
					
						Output Wattage Rating:
					
					
						600.0 watts  single power output					
				 
							
					
						MRC:
						The output current rating at which the item is designed to operate.CWGH
					 
					
						Output Current Rating:
					
					
						1000.0 ac volt-ampere  single power output					
				 
							
					
						MRC:
						The number of output alternating current phases.CWGN
					 
					
						Output Phase:
					
					
						Single single power output					
				 
							
					
						MRC:
						The number of electrical output connections on the item.CWHF
					 
					
						Output Connection Quantity:
					
					
						6 single power output					
				 
							
					
						MRC:
						Indicates the type of electrical output connection.CWHJ
					 
					
						Output Connection Type:
					
					
						Connector  plug single power output					
				 
							
					
						MRC:
						Indicates the type of electrical input connection.CWHQ
					 
					
						Input Connection Type:
					
					
						Connector  plug single operating power rqmt					
				 
							
					
						MRC:
						An indication of whether or not the battery is rechargeable and the type of battery.CWHY
					 
					
						Battery Feature And Type:
					
					
						Rechargeable lead acid cell					
				 
							
					
						MRC:
						The emergency operating time a battery power supply can deliver full rated output voltage/current before the output drops below a specified value.CXMX
					 
					
						Battery Power Supply Emergency Operating Time:
					
					
						7.4