Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
NSN
Número de acciones nacionales:
TXT
Descripción:
Power Supply
Código de nombre del artículo:
00740
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
7.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.688 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.875 inches
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single single operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
110.0 ac volts single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
18.0 ac volts 3RD power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
24.0 ac volts 2ND power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
24.0 dc volts 1ST power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
10.0 ac volts 4TH power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
6.0 ac volts 5TH power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
60.0 hertz single operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
+0.1/+50.0 degrees celsius
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
1 5TH power output
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
1 1ST power output
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
1 2ND power output
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
1 3RD power output
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
1 4TH power output
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Voltage adjustment 2ND power output
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Voltage adjustment 3RD power output
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Voltage adjustment 1ST power output
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Voltage adjustment 4TH power output
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Voltage adjustment 5TH power output
MRC:
The means used to change alternating current voltage to direct current voltage.BHQN
Rectification Method:
Single phase full wave center tap
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Filter
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
2.0 ac amperes 2ND power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
2.0 ac amperes 3RD power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
2.0 ac amperes 4TH power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
2.0 ac amperes 5TH power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
700.0 dc milliamperes 1ST power output
MRC:
Indicates the location of the output control(s).CWHC
Output Control Location:
Front panel 1ST power output
MRC:
Indicates the location of the output control(s).CWHC
Output Control Location:
Front panel 2ND power output
MRC:
Indicates the location of the output control(s).CWHC
Output Control Location:
Front panel 3RD power output
MRC:
Indicates the location of the output control(s).CWHC
Output Control Location:
Front panel 4TH power output
MRC:
Indicates the location of the output control(s).CWHC
Output Control Location:
Front panel 5TH power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
4 1ST power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
4 2ND power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
4 3RD power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
4 4TH power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
4 5TH power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Terminal strip 1ST power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Terminal strip 2ND power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Terminal strip 3RD power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Terminal strip 4TH power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Terminal strip 5TH power output