Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
s10-6506-4
NSN
Número de acciones nacionales:
TXT
Descripción:
Electrical Special Purpose Cable
Código de nombre del artículo:
16488
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
105.0 degrees celsius
MRC:
The length of a straight line which passes through the center of a cross section,and terminates at the outside circumference.ADVL
Cross Section Outside Diameter:
0.340 inches
MRC:
The number of electrical conductors included on the item.AMQN
Conductor Quantity:
7
MRC:
The number of strands per conductor.BLNZ
Strand Quantity Per Conductor:
19 4TH conductor
MRC:
The number of strands per conductor.BLNZ
Strand Quantity Per Conductor:
19 5TH conductor
MRC:
The number of strands per conductor.BLNZ
Strand Quantity Per Conductor:
7 6TH conductor
MRC:
The number of strands per conductor.BLNZ
Strand Quantity Per Conductor:
7 7TH conductor
MRC:
The number of strands per conductor.BLNZ
Strand Quantity Per Conductor:
7 1ST conductor
MRC:
The number of strands per conductor.BLNZ
Strand Quantity Per Conductor:
7 2ND conductor
MRC:
The number of strands per conductor.BLNZ
Strand Quantity Per Conductor:
7 3RD conductor
MRC:
The fabricated form of the conductor.CXCW
Conductor Form:
Stranded all conductors
MRC:
The designation used to describe the round stranded or round solid conductor size.CXDC
Round Conductor Size:
14 awg 4TH conductor
MRC:
The designation used to describe the round stranded or round solid conductor size.CXDC
Round Conductor Size:
14 awg 5TH conductor
MRC:
The designation used to describe the round stranded or round solid conductor size.CXDC
Round Conductor Size:
22 awg 1ST conductor
MRC:
The designation used to describe the round stranded or round solid conductor size.CXDC
Round Conductor Size:
22 awg 2ND conductor
MRC:
The designation used to describe the round stranded or round solid conductor size.CXDC
Round Conductor Size:
22 awg 3RD conductor
MRC:
The designation used to describe the round stranded or round solid conductor size.CXDC
Round Conductor Size:
22 awg 6TH conductor
MRC:
The designation used to describe the round stranded or round solid conductor size.CXDC
Round Conductor Size:
22 awg 7TH conductor
MRC:
The american wire gage size of the individual strands of wire used in each stranded conductor.CXDG
Strand Awg Size Per Conductor:
27 4TH conductor
MRC:
The american wire gage size of the individual strands of wire used in each stranded conductor.CXDG
Strand Awg Size Per Conductor:
27 5TH conductor
MRC:
The american wire gage size of the individual strands of wire used in each stranded conductor.CXDG
Strand Awg Size Per Conductor:
30 1ST conductor
MRC:
The american wire gage size of the individual strands of wire used in each stranded conductor.CXDG
Strand Awg Size Per Conductor:
30 2ND conductor
MRC:
The american wire gage size of the individual strands of wire used in each stranded conductor.CXDG
Strand Awg Size Per Conductor:
30 3RD conductor
MRC:
The american wire gage size of the individual strands of wire used in each stranded conductor.CXDG
Strand Awg Size Per Conductor:
30 6TH conductor
MRC:
The american wire gage size of the individual strands of wire used in each stranded conductor.CXDG
Strand Awg Size Per Conductor:
30 7TH conductor
MRC:
The arrangement and number of arrangements of the conductors.CXDQ
Conductor Arrangement And Quantity:
5 singles and 1 twisted pair
MRC:
The number of groups into which two or more conductors are arranged.CXDT
Group Quantity:
1
MRC:
Indicates the type and number of conductor arrangements within groups.CXDY
Conductor Grouping Arrangement Type And Quantity:
1 twisted pair first group
MRC:
The identification of the conductors within a group.CXFG
Conductor Sequence Within Groups:
Sixth conductor first group and seventh conductor first group
MRC:
The maximum sustained voltage that can be safely applied to the item without risking failure or damage.CXFK
Voltage Rating:
600.0 root mean square (rms) operating voltage 1ST conductor
MRC:
The maximum sustained voltage that can be safely applied to the item without risking failure or damage.CXFK
Voltage Rating:
600.0 root mean square (rms) operating voltage 2ND conductor
MRC:
The maximum sustained voltage that can be safely applied to the item without risking failure or damage.CXFK
Voltage Rating:
600.0 root mean square (rms) operating voltage 3RD conductor
MRC:
The maximum sustained voltage that can be safely applied to the item without risking failure or damage.CXFK
Voltage Rating:
600.0 root mean square (rms) operating voltage 6TH conductor
MRC:
The maximum sustained voltage that can be safely applied to the item without risking failure or damage.CXFK
Voltage Rating:
600.0 root mean square (rms) operating voltage 7TH conductor
MRC:
The maximum sustained voltage that can be safely applied to the item without risking failure or damage.CXFK
Voltage Rating:
1000.0 root mean square (rms) operating voltage 4TH conductor
MRC:
The maximum sustained voltage that can be safely applied to the item without risking failure or damage.CXFK
Voltage Rating:
1000.0 root mean square (rms) operating voltage 5TH conductor
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Black 11TH position conductor seventh conductor
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Black 11TH position conductor fifth conductor
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Orange 11TH position conductor third conductor
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Red 11TH position conductor fourth conductor
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
White 11TH position conductor sixth conductor
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Blue 11TH position conductor second conductor
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Yellow 11TH position conductor first conductor
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Yellow 7TH position conductor cable
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper 16TH position conductor first group
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper core conductor all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic polyvinyl chloride 11TH position conductor all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic polyvinyl chloride 7TH position conductor cable
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Astm B33 assn standard single material response core conductor all conductors
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
MIL-I-631 class f military specification single material response 7TH position conductor cable
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Tin 16TH position conductor first group
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Tin core conductor all conductors
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as type,class,grade,and the like,that identifies the surface treatment material.STDC
Surface Treatment Specification:
Astm B33 assn standard single treatment response core conductor all conductors
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as type,class,grade,and the like,that identifies the surface treatment material.STDC
Surface Treatment Specification:
Astm B33 assn standard single treatment response 16TH position conductor first group