Número de pieza RM561

Oscilloscope

Precios y disponibilidad

Envíe este formulario para conocer los precios actuales y la disponibilidad de esta NSN.
Número de pieza:
Cantidad:
Dirección de correo electrónico:
Teléfono:
Referencia:
Compañía:
Nombre:

No compartimos ni vendemos su información a nadie.
Privacidad | Letra chica

All major credit cards accepted as well as gov. p-cards
Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
rm561
Desmilitarización:
Yes - DEMIL/MLI
Vigencia:
Unidad de medida:
NIIN:
009684564

Información de la pieza
Y-axis frequency response rating dc to 4 mc per sec

NSN
Número de acciones nacionales:
6625-00-968-4564 6625009684564
TXT
Descripción:
Oscilloscope
INC
INC
Código de nombre del artículo:
00357
INC
COM
Conformidad:
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
18.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
7.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
19.000 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 60.0 hertz
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Type no AN/FSQ-41V
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
Adapter connector 1, cable assembly power 1, technical manual 2
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
Between 110.0 volts and 250.0 volts
MRC:
The number of beams provided on the item.ATES
Beam Quantity:
1
MRC:
The interval/s/ as indicated by the markings on the item.AWEC
Graduation Interval:
Graduated in timb/cm on x-axis and v/cm on y-axis
MRC:
The means of attaching the item.AXGY
Mounting Method:
Rack
MRC:
The acceptable limits of deviation from the designed standard output value of the item,expressed in percent.BDJD
Accuracy Range In Percent:
-3.0/+3.0
MRC:
Designates the relative or proportionate dimensions of the screen.BGQK
Screen Size:
5 in
MRC:
An indication of whether or not sweep circuits are included.BGQL
Sweep Circuits:
Not included
MRC:
An indication of whether or not provisions for rating the deflection sensitivity through the amplifier are provided.BHDD
Amplifier Deflection Sensitivity Provision:
Not provided
MRC:
An indication of whether or not an input intensity modulation feature is provided.BHDH
Input Intensity Modulation Feature:
Not provided
MRC:
An indication of whether or not provisions for rating the direct connection to the plate deflection sensitivity is provided.BHDL
Plate Direct Connection Deflection Sensitivity Provision:
Not provided
MRC:
An indication of whether or not a frequency response rating is provided.BHDP
Frequency Response Rating:
Provided
MRC:
An indication of whether or not amplifier input impedance rating is provided.BHDT
Amplifier Input Impedance Rating Provision:
Not provided
MRC:
An indication of the shape of the amplitude calibrating voltage waveform.BHDZ
Amplitude Calibrating Voltage Waveform:
Square wave
MRC:
The peak to peak value for which the item is calibrated.BHFB
Calibrating Peak To Peak Amplitude:
Between 0.2 millivolts and 100.0 volts
MRC:
The number of measurement ranges included.BHFC
Measurement Range Quantity:
18
MRC:
An indication as to the measurement capabilities of the range or ranges.BHFD
Measurement Range Steps:
0.2, 0.5, 1, 2, 5, 10, 20 and 50 mv 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50 and 100 v
MRC:
An indication of whether or not a calibrated screen scale is included.BHFF
Calibrated Screen Scale:
Included
MRC:
An indication of whether or not a trace storage tube is included.BHFH
Trace Storage Tube:
Not included
MRC:
An indication of the function of the plug in units and the number provided.BHFS
Plug In Unit Function And Quantity:
1 vertical amplifier 1 horizontal time base
MRC:
An indication of whether or not camera recording device accommodations are provided.BHFT
Camera Recording Device Accommodation:
Provided
MRC:
The number of alternating current phases.FAAZ
Phase:
Single and single

Similar Oscilloscopes

« Electrical and Electronic Properties Measuring and Testing Instruments Catálogo
Comparar ahora»
Claro | Esconder