Número de pieza
					Desmilitarización
					Vigencia
					UOM
					NIIN
				 
				
					
						Número de pieza:
						radcal9010					
 
					
						Desmilitarización:
						Yes - DEMIL/MLI					 
					
					
					
				 
			 
							
					
						Información de la pieza
						Dfunctions auto zero  dose rate  maximum dose rate  dose  auto dose  pulsed cine lcd display test lcd display verification;  battery test checks battery voltage  chamber voltage test checks bias voltage
					 
				 
						
				
					NSN
				
				
					Número de acciones nacionales:
				
				
			 
			
				
					TXT
				
				
					Descripción:
				
				
					Radiac Set				
			 
			
				
				
					Código de nombre del artículo:
				
				
					07331				
			 
							
										
					
						MRC:
						Indicates the designed use of the item.ALCD
					 
					
						Usage Design:
					
					
						X-ray service  x-ray qa and compliance  x-ray acceptance testing  industrial applications,  medical and health physics  therapy qa  secondary standards  nuclear applications,  radiography,  fluoroscopy,  angiography,  mammography;  image intensifier;  pulsed x-ray  cine  ct  dental  137CS;  60CO irradiator measurements;  survey meter calibration;  industrial x-ray  cables up to 300 feet  very low dose rates and very high dose rate applications,  up to 107R/HR with special modification					
				 
							
					
						MRC:
						An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
					 
					
						Internal Battery Accommodation:
					
					
						Included					
				 
							
					
						MRC:
						Indicates the type of device used to register the condition(s).AMKD
					 
					
						Indicator Type:
					
					
						Visual					
				 
							
					
						MRC:
						Indicates the radiation type and function.AMRM
					 
					
						Radiation Type And Function:
					
					
						X-rays detects					
				 
							
					
						MRC:
						Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
					 
					
						Functional Description:
					
					
						Multipurpose dosemeters					
				 
							
					
						MRC:
						Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
					 
					
						Supplementary Features:
					
					
						Porm 4 pct of reading  porm 1 digit  porm 2 times resolution  repeatability porm 1 pct of reading  porm 1 digit  porm 2 times resolution  auto temperature accuracy 2 pct  auto pressure accuracy 0.2 pct  plus 2 pct of reference pressure-ambient,  optional specify opt-p  analog capture 0-5 v  10KHZ,  12 bit analog to digital signal capture  100 usec and 1.25 mv resolution OVER1 sec  playback to analog output  data available at the RS-232 port or anlaog out  timing 5 ms to 6.5 sec with 100USEC resolution with porm 0.05 pct accuracy  exclusive of non-invasive detector  infrared remote allows full control from up to 10 m away  will go through lead glass