Número de pieza PM1

Radiac Calibrator Set

Precios y disponibilidad

Envíe este formulario para conocer los precios actuales y la disponibilidad de esta NSN.
Número de pieza:
Cantidad:
Dirección de correo electrónico:
Teléfono:
Referencia:
Compañía:
Nombre:

No compartimos ni vendemos su información a nadie.
Privacidad | Letra chica

All major credit cards accepted as well as gov. p-cards
Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
pm1
Desmilitarización:
No
Vigencia:
N/A
Unidad de medida:
1 EA
NIIN:
013700545

Información de la pieza
Chambers: A3 3/8 in radius 3.6 vol cc 0.0 r/nc cal factor A4 - 3/4 in rad 30 cc volume 0.09 r/nc cal A51-1/8 in radius 100 cc vol 0.03 r/nccal A6 - 2-1/4 in Rad 800 cc vol 0.004 r/nc cal laser: 1-6 meters/sec velocity 2 g's acceleration; distance .17-30 meters elevataion porm 60 deg electrometer: 200 MV-200 v range 10 UV-10 mv resolution power supply: 0-3 kv dc output thermometer: 0.1 degrees resolution displays degrees f Or c barometer: 0.5-19 psia 3.5-130 kpaa

NSN
Número de acciones nacionales:
6665-01-370-0545 6665013700545
TXT
Descripción:
Radiac Calibrator Set
INC
INC
Código de nombre del artículo:
00396
MRC:
The number of parts supplied with the item which may be required for application.AFHS
Accessory Component Quantity:
1 and 1 and 1 and 1 and 1 and 1 and 1 and 1 and 1 and 1
MRC:
The number of components included in the item.AJJW
Component Quantity:
6
MRC:
A listing of those major components which are comprised of a national stock number,an item name,standardized name,or part name,and the number of each.AJKC
Supply Items And Quantities:
R6130-01-174-0653 power supply 1; 6625-01-251-5909 multimeter 1; digitalthermometer 1; dosimeter 1; electronicbarometer 01; cavity ionization chamber 4; coaxial termination 1; laser measurement system 1; electrometer 1
MRC:
The name of the government agency or commercial organization that controls the manufacture of the accessory item.AKVY
Accessory Controlling Agency:
Keithley instruments inc kitrickmanagement co ruska instrument co exradin inc exradin inc chesapeake laser systems inc
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Calibrates gamma radiation sources (standards) model 81-10 on site electrometer used to measure charge accumulated by ionization chamber barometer and thermometer measure pressure andtemperature at point of measurement; laser measurement system measures distance from radiation source to detector and used to calibrate radiation track system