Número de pieza MR3220A1

Constant Temperature Bath

Precios y disponibilidad

Envíe este formulario para conocer los precios actuales y la disponibilidad de esta NSN.
Número de pieza:
Cantidad:
Dirección de correo electrónico:
Teléfono:
Referencia:
Compañía:
Nombre:

No compartimos ni vendemos su información a nadie.
Privacidad | Letra chica

All major credit cards accepted as well as gov. p-cards
Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
mr3220a1
Desmilitarización:
No
Vigencia:
N/A
Unidad de medida:
1 EA
NIIN:
004715688

Información de la pieza
Double wall o/a dim 27 in L 28 in W 17.0 in H freon 12 hermetically sealed compressor fan cooled condenser expansion valve metering system 115 vac 50/60 hz 1600 watts

NSN
Número de acciones nacionales:
6640-00-471-5688 6640004715688
TXT
Descripción:
Constant Temperature Bath
INC
INC
Código de nombre del artículo:
32951
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
An inside measurement taken at right angles to the length of an item,in distinction from thickness.ADJT
Inside Width:
12.000 inches
MRC:
A measurement of the longest inside dimension of an item,in distinction from width.ADJU
Inside Length:
18.000 inches
MRC:
An inside measurement between specified points of an item,in distinction from height.AFEF
Inside Depth:
7.000 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+0.0/+100.0 degrees celsius
MRC:
An indication of whether or not an insulated feature is included.AHGR
Insulated Feature:
Included
MRC:
A measurement of the capacity of an item.BBLT
Capacity Rating:
6.200 gallons
MRC:
The element,compound,or mixture of which the reservoir is fabricated,excluding any surface treatment.BNDF
Reservoir Material:
Steel
MRC:
An indication of whether or not a test tube rack is included.BNDM
Test Tube Rack:
Not included
MRC:
An indication of whether or not an agitator is included.BNDQ
Agitator:
Included
MRC:
An indication of whether or not a thermoregulator is included.BNDR
Thermoregulator:
Included
MRC:
An indication of whether or not cooling coils for below room temperature use are included.BNDW
Cooling Coils For Below Room Tempurature Use:
Included
MRC:
An indication of whether or not a pilot light is included.BNDY
Pilot Light:
Included
MRC:
The physical configuration of the item.SHPE
Shape:
Rectangular

Similar Constant Temperature Bathes