Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
milr22307
Desmilitarización:
Yes - DEMIL/MLI
NSN
Número de acciones nacionales:
TXT
Descripción:
Radiac Set
Código de nombre del artículo:
07331
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
The number of parts supplied with the item which may be required for application.AFHS
Accessory Component Quantity:
1
MRC:
The number of parts supplied with the item which may be required for application.AFHS
Accessory Component Quantity:
2
MRC:
The number of parts supplied with the item which may be required for application.AFHS
Accessory Component Quantity:
1 3RD accessory
MRC:
The number of parts supplied with the item which may be required for application.AFHS
Accessory Component Quantity:
1 4TH accessory
MRC:
The number of parts supplied with the item which may be required for application.AFHS
Accessory Component Quantity:
1 5TH accessory
MRC:
The number of parts supplied with the item which may be required for application.AFHS
Accessory Component Quantity:
1 6TH accessory
MRC:
The number of parts supplied with the item which may be required for application.AFHS
Accessory Component Quantity:
1 1ST accessory
MRC:
The number of parts supplied with the item which may be required for application.AFHS
Accessory Component Quantity:
2 2ND accessory
MRC:
Items furnished as accessories which are not specified elsewhere.AFJH
Furnished Items:
Radiac set case plastic cover radiacmeter, radioactive test sample carrying strap technical manual
MRC:
The name of the government agency or commercial organization that controls the manufacture of the accessory item.AKVY
Accessory Controlling Agency:
Jetds electronic products co jetds jetds jetds buships
MRC:
The specific number used to identify the accessory.AKVZ
Accessory Identifying Number:
Dwg no 506-132
MRC:
The specific number used to identify the accessory.AKVZ
Accessory Identifying Number:
Navships 93562
MRC:
The specific number used to identify the accessory.AKVZ
Accessory Identifying Number:
Type MX-2608/PDR-43
MRC:
The specific number used to identify the accessory.AKVZ
Accessory Identifying Number:
Type no IM-125A/PDR-43
MRC:
The specific number used to identify the accessory.AKVZ
Accessory Identifying Number:
Type no CY-2073/PDR-43
MRC:
The specific number used to identify the accessory.AKVZ
Accessory Identifying Number:
Type no ST-134/U
MRC:
The specific number used to identify the accessory.AKVZ
Accessory Identifying Number:
Dwg no 506-132 2ND accessory
MRC:
The specific number used to identify the accessory.AKVZ
Accessory Identifying Number:
Navships 93562 6TH accessory
MRC:
The specific number used to identify the accessory.AKVZ
Accessory Identifying Number:
Type MX-2608/PDR-43 4TH accessory
MRC:
The specific number used to identify the accessory.AKVZ
Accessory Identifying Number:
Type no CY-2073/PDR-43 1ST accessory
MRC:
The specific number used to identify the accessory.AKVZ
Accessory Identifying Number:
Type no IM-125A/PDR-43 3RD accessory
MRC:
The specific number used to identify the accessory.AKVZ
Accessory Identifying Number:
Type no ST-134/U 5TH accessory
MRC:
The name assigned to the item by the joint electronics type designation system.AKWA
Joint Electronics Type Designation System Item Name:
Radiac set
MRC:
The type number assigned to the item by the joint electronics type designation system.AKWB
Joint Electronics Type Designation System Item Type Number:
Type no AN/PDR-43B
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Included
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Meter
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
Beta rays detects
MRC:
Indicates the radiation type and function.AMRM
Radiation Type And Function:
Gamma rays measures
MRC:
Indicates the type of detecting element included.AMRX
Detecting Element Type:
Geiger tube
MRC:
The minimum and maximum amount of radiation detected per hour.APPJ
Radiation Range Per Hour:
+0.0/+500.0 roentgens
MRC:
The minimum and maximum amount of radiation detected per hour.APPJ
Radiation Range Per Hour:
+0.0 to 500.0 roentgens
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-20.0/+20.0 all ranges
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-20.0 to 20.0 all ranges
MRC:
The value of electrical potential to which an item will respond.APPP
Input Sensitivity Voltage Rating:
Not rated
MRC:
An indication of the energy dependence rating of the item.APPQ
Energy Dependence Rating:
80.000 kev to 2.000 mev
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
3.0