Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
m845a1035
NSN
Número de acciones nacionales:
TXT
Descripción:
Rota Electro-mechanical Actuator
Código de nombre del artículo:
11006
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Wire leads
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
15.0 degrees fahrenheit and 125.0 degrees fahrenheit
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
7.750 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
5.625 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
6.188 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Vibration
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Counterclockwise
MRC:
Indicates the type of drive for turning,rotating,or positioning the mechanism.AKCV
Drive Type:
Gear
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Adjustable
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
3.6 and 7.2
MRC:
The measurement of rotation,expressed in degrees.AWQL
Rotation In Deg:
Between 90.0 and 160.0
MRC:
The rated torque of the output drive.AWQM
Output Drive Torque Rating:
50.0 inch-pounds
MRC:
An indication of whether or not a limit switch control is included.AWQN
Limit Switch Control:
Included
MRC:
An indication of whether or not a manual override is included.AWQR
Manual Override:
Not included
MRC:
An indication of the rotation of the angular shaft.AWTZ
Angular Shaft Rotation:
Limited
MRC:
The maximum operating on time and the minimum off time for a complete cycle of an item.AYEK
Intermittent Operation Duty Cycle:
60.0 seconds on and 35.0 seconds off
MRC:
The facility for mounting the item.AZGM
Mounting Facility:
Unthreaded mounting holes
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
120.0 and 240.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
50.0 and 60.0