Número de pieza
					Desmilitarización
					Vigencia
					UOM
					NIIN
				 
				
					
						Número de pieza:
						kc20-018025					
 
					
					
					
					
				 
			 
						
				
					NSN
				
				
					Número de acciones nacionales:
				
				
			 
			
				
					TXT
				
				
					Descripción:
				
				
					 Nonwire Wound Variable Resistor				
			 
			
				
				
					Código de nombre del artículo:
				
				
					37407				
			 
										
					
						MRC:
						The number of individual elements.AAPN
					 
					
						Section Quantity:
					
					
						1					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						Cylindrical servo mounted					
				 
							
					
						MRC:
						An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
					 
					
						Reliability Indicator:
					
					
						Not established					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of that portion used to guide the item and terminates at the circumference.AAVL
					 
					
						Pilot Diameter:
					
					
						1.8750 inches 					
				 
							
					
						MRC:
						The length of the pilot,which is the unthreaded portion beyond the thread used to guide the item.AAVM
					 
					
						Pilot Length:
					
					
						Between 0.0300 inches and 0.0900 inches 					
				 
							
					
					
						Undercut Diameter:
					
					
						1.875 inches 					
				 
							
					
					
						Undercut Width:
					
					
						0.0600 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
					 
					
						Body Diameter:
					
					
						2.000 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
					 
					
						Shaft Diameter:
					
					
						0.250 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the shaft,in distinction from width.ABXF
					 
					
						Shaft Length:
					
					
						0.750 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						0.865 inches 					
				 
							
					
					
						Mounting Lip Diameter:
					
					
						2.0000 inches 					
				 
							
					
					
						Mounting Lip Depth:
					
					
						Between 0.0500 inches and 0.1000 inches 					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the shaft.AEDX
					 
					
						Shaft Style:
					
					
						Round					
				 
							
					
						MRC:
						Indicates the type of shaft bearing/s/ furnished.AEDZ
					 
					
						Shaft Bearing Type:
					
					
						Bearing					
				 
							
					
						MRC:
						Indicates the type of facility or arrangement provided for moving the variable contact(s).AEFD
					 
					
						Actuator Type:
					
					
						Single shaft					
				 
							
					
						MRC:
						That part of the total rotational travel of the actuator that produces a change in output,expressed in degree angular rotation.AEFH
					 
					
						Effective Electrical Rotation In Deg Angular Rotation:
					
					
						360.0 					
				 
							
					
						MRC:
						The maximum amount of turning force required to initiate the actuator movement.AEFK
					 
					
						Maximum Starting Torque:
					
					
						2.00 inch-ounces					
				 
							
					
						MRC:
						The maximum amount of force requred to maintain actuator movement.AEFL
					 
					
						Maximum Running Torque:
					
					
						2.00 inch-ounces					
				 
							
					
						MRC:
						The total radial excursion of the shaft measured at a specified distance from the front surface of the unit with a specified radial load applied alternately in opposite directions at a specified point.AEGC
					 
					
						Shaft Radial Play:
					
					
						0.003 inches					
				 
							
					
						MRC:
						The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.AFJN
					 
					
						Fragility Factor:
					
					
						Moderately rugged					
				 
							
					
						MRC:
						The position of the terminal/s/ for making connection to an item.APXH
					 
					
						Terminal Location:
					
					
						Radially positioned over more than half the circumference					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Clamp ring					
				 
							
					
						MRC:
						Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
					 
					
						Features Provided:
					
					
						Humidity proof					
				 
							
					
						MRC:
						A measure of the opposition to the flow of direct or alternating current per section.CQCC
					 
					
						Electrical Resistance Per Section:
					
					
						22.0 kilohms single section					
				 
							
					
						MRC:
						The location per section,in degrees,of effective electrical rotation between the counterclockwise terminal of a resistor and each tap terminal.CQCH
					 
					
						Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation:
					
					
						30.0 single section					
				 
							
					
						MRC:
						The measurement of the rotary mechanical motion of the actuating shaft of an item,expressed in degrees.CQCK
					 
					
						Rotary Actuator Travel In Angular Deg:
					
					
						360.0 					
				 
							
					
						MRC:
						The permissible range per section by which the actual value of resistance or voltage at any specified point may deviate from the theoretical value for the linear or nonlinear function,expressed as a minus and plus percent.CQFL
					 
					
						Function Conformity Tolerance Per Section:
					
					
						-1.00/+1.00 single section					
				 
							
					
						MRC:
						The fidelity of the relationship between the actual function characteristics and the theoretical function per section.CRGM
					 
					
						Function Conformity Per Section:
					
					
						Single section absolute conformity					
				 
							
					
						MRC:
						The number of fixed terminals at points between the end terminals that provide connection to the intermediate values of the total value per section.CRJS
					 
					
						Fixed Tap Quantity Per Section:
					
					
						1 single section					
				 
							
					
						MRC:
						The limits of permissible variation from the rated value of the location of a tap per section.CRKS
					 
					
						Tap Location Tolerance Per Section:
					
					
						-1.0/+1.0 degrees angular rotation single section					
				 
							
					
						MRC:
						The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.CRSS
					 
					
						Resistance Tolerance Per Section In Percent:
					
					
						-10.0/+10.0 single section					
				 
							
					
						MRC:
						The feature that controls the actuator travel.CRSX
					 
					
						Actuator Travel Control Feature:
					
					
						Clutch					
				 
							
					
						MRC:
						The specified mathematical relation per section between the terminal resistance,or output ratio,and the rotation of the actuator.CSBX
					 
					
						Function Characteristic Per Section:
					
					
						Single section 360 degrees sine-cosine					
				 
							
					
						MRC:
						The ambient temperature,expressed in degrees celsius,of the medium surrounding each section at which it can be operated continuously at full rated power.CSDH
					 
					
						Ambient Tempurature In Deg Celsius Per Section At Full Rated Power:
					
					
						85.0 single section					
				 
							
					
						MRC:
						The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
					 
					
						Test Data Document:
					
					
						24930-112755 drawing (this is the basic governing drawing  such as a contractor drawing  original equipment manufacturer drawing  etc  excludes any specification,  standard or other document that may be referenced in a basic governing drawing)					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						6 turret