Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
kaw1100m1
Información de la pieza
Options include IEEE488.2/RS232 configuration; forced air cooling fans
NSN
Número de acciones nacionales:
TXT
Descripción:
Radio Frequency Amplifier
Código de nombre del artículo:
00446
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
21.0 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
7.0 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
19.0 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-10.0 to 40.0 degrees celsius
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Not rated
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Module
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
10.0 kilohertz 1ST operating channel and 200.0 megahertz 1ST operating channel and 200.0 megahertz 2ND operating channel and 1000.0 megahertz 2ND operating channel
MRC:
The increase in energy from the input to the output.BHTL
Overall Gain:
47.0 decibels
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
50.0 ohms input channel and 50.0 ohms output channel
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
47.0 single voltage and 63.0 single voltage
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
85.0 single voltage and 265.0 single voltage
MRC:
The number of alternating current phases.FAAZ
Phase:
Single