Número de pieza GGC411

Laboratory Utility Clamp
Descripción

Clamp,utility,labor

Precios y disponibilidad

Envíe este formulario para conocer los precios actuales y la disponibilidad de esta NSN.
Número de pieza:
Cantidad:
Dirección de correo electrónico:
Teléfono:
Referencia:
Compañía:
Nombre:

No compartimos ni vendemos su información a nadie.
Privacidad | Letra chica

All major credit cards accepted as well as gov. p-cards
Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
ggc411
Desmilitarización:
No
Vigencia:
Unidad de medida:
NIIN:
001303238
NSN
Número de acciones nacionales:
6640-00-130-3238 6640001303238
TXT
Descripción:
Laboratory Utility Clamp
INC
INC
Código de nombre del artículo:
21996
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
7.000 inches
MRC:
The means used to attach the item.ABSX
Attachment Method:
Rod clamp
MRC:
The element,compound,or mixture of which the sleeve is fabricated.AFTB
Sleeve Material:
Vermiculite
MRC:
The structural characteristic of the item.ARQS
Construction:
Round
MRC:
Indicates the type of jaw furnished with the item.ASYY
Jaw Type:
Single
MRC:
The means used to adjust the jaw arms.BNGF
Jaw Arms Adjustment Method:
Single nut
MRC:
The maximum length of a straight line which passes through the center of the clamping for which the item is designed,and terminates at the circumference.BNGG
Maximum Clamping Diameter:
1.500 inches
MRC:
An indication of whether or not a swivel jaw is provided.BNGH
Swivel Jaw:
Not provided
MRC:
An indication of whether or not a means is provided for integral attachment.BNGJ
Integral Attachment Provision:
Provided
MRC:
Indicates the location of an item which has the attachment facility.BNGK
Err Default:
Err default
MRC:
Indicates the location of an item which has the attachment facility.BNGK
Attachment Facility Location:
End
MRC:
The maximum length of a straight line which passes through the center of the clamping for which the rod is designed,and terminates at the circumference.BNGL
Err Default:
Err default
MRC:
The maximum length of a straight line which passes through the center of the clamping for which the rod is designed,and terminates at the circumference.BNGL
Rod Maximum Clamping Diameter:
0.750 inches
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Zinc alloy QQ-Z-363, comp a
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Zinc alloy uns Z33520
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects a surface.SURF
Surface Treatment:
Nickel plated
MRC:
The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
Specification Or Standard:
Ii composition and 2 type
MRC:
The variation when the item is in conformity with a type designator covered by a specification or standard,except in regard to one or more technical differentiating characteristics.ZZZX
Departure From Cited Designator:
Bngg and bngl

Similar Laboratory Utility Clamps

« Laboratory Equipment and Supplies Catálogo