Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Información de la pieza
Flowmeter
NSN
Número de acciones nacionales:
TXT
Descripción:
Flow Rate Indicating Meter
Código de nombre del artículo:
38346
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
8.375 inches
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Water
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Threaded
MRC:
An indication of the type of meter.ANTH
Meter Type:
Float
MRC:
Indicates the type of unit.APQB
Unit Type:
Mounted
MRC:
The number of scales on the item.APSJ
Scale Quantity:
2
MRC:
A narrative description of the type of outlet connection.ARTH
Outlet Connection Type:
Threaded
MRC:
The number of floats provided.AWAE
Float Quantity:
1
MRC:
The element,compound,or mixture of which the tube is fabricated,excluding any surface treatment.AWGJ
Tube Material:
Plastic
MRC:
The means of attaching the item.AXGY
Mounting Method:
Surface panel
MRC:
Designates the size of the outlet connection included on the item.BHCM
Outlet Connection Size:
0.500 in
MRC:
The element,compound,or mixture of which the float is fabricated,excluding any surface treatment.BJDM
Float Material:
Steel stainless
MRC:
An indication of whether or not an integral heat source is included.BNHN
Integral Heat Source:
Not included
MRC:
The maximum working pressure at which an item is designed to operate.BPHD
Maximum Working Pressure:
250.0 pounds per square inch
MRC:
Designates the size of the inlet connection included on the item.CPZD
Inlet Connection Size:
0.500 in
MRC:
The number of metering tubes provided.CPZF
Metering Tube Quantity:
1
MRC:
The maximum amount of water for which the item is rated,expressed in gallons per minute.CPZG
Maximum Water Capacity In Gallons Per Minute:
2.0
MRC:
The inlet connection position for which the item is designed.CPZP
Inlet Connection Position For Which Designed:
Horizontal
MRC:
Indicates the type of inlet connection device provided.CPZQ
Inlet Connection Device Type:
Stationary
MRC:
The outlet connection position for which the item is designed.CPZR
Outlet Connection Position For Which Designed:
Horizontal
MRC:
Indicates the type of outlet connection device provided.CPZS
Outlet Connection Device Type:
Stationary
MRC:
An indication of whether or not an alarm signal is included.CPZT
Alarm Signal:
Not included
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Adjustable meter permanent silk screen dual scale water calibration; 2 psi ful scale max Pressure drop