Número de pieza
					Desmilitarización
					Vigencia
					UOM
					NIIN
				 
				
					
						Número de pieza:
						da868p75sem					
 
					
					
					
					
				 
			 
						
				
					NSN
				
				
					Número de acciones nacionales:
				
				
			 
			
				
					TXT
				
				
					Descripción:
				
				
					Expansion Valve				
			 
			
				
				
					Código de nombre del artículo:
				
				
					05493				
			 
										
					
						MRC:
						The basic material of which the body is fabricated.AAFZ
					 
					
						Body Material:
					
					
						Bronze					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
					 
					
						Body Style:
					
					
						C1 straight thru					
				 
							
					
						MRC:
						The type of service with which the item is designed to be used.ACKL
					 
					
						Media For Which Designed:
					
					
						Refrigerant 12					
				 
							
					
						MRC:
						A narrative description of the type of end connection.ACKM
					 
					
						First End Connection Type:
					
					
						Threaded internal pipe					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
					 
					
						First End Style Designator:
					
					
						Plain					
				 
							
					
						MRC:
						The industrial designation or term used to define the nominal diameter of the pipe the end will accommodate.ACLG
					 
					
						First End Pipe Size Accommodated:
					
					
						0.750 inches					
				 
							
					
						MRC:
						The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACLL
					 
					
						First End Thread Direction:
					
					
						Right-hand					
				 
							
					
						MRC:
						Indicates whether or not the second end is identical to the first end.ACLR
					 
					
						Second End Relationship With First End:
					
					
						Identical					
				 
							
					
						MRC:
						The part that controls the flow through the item.ADQU
					 
					
						Flow Control Device:
					
					
						Piston  spring loaded					
				 
							
					
						MRC:
						The number of end connections included in the item.ADQZ
					 
					
						End Connection Quantity:
					
					
						2					
				 
							
					
						MRC:
						The minimum to maximum pressures at which the item may be adjusted.ADSW
					 
					
						Adjustable Pressure Range:
					
					
						+70.0/+260.0 pounds per square inch					
				 
							
					
						MRC:
						A measurement of the longest dimension of a capillary tube.AEVT
					 
					
						Capillary Tube Length:
					
					
						42.000 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of a bulb.AEVU
					 
					
						Bulb Length:
					
					
						2.000 inches 					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of the bulb,and terminates at the circumference.AEVV
					 
					
						Bulb Diameter:
					
					
						0.250 inches 					
				 
							
					
						MRC:
						Indicates the type of control by which the valve is expanded.AFKK
					 
					
						Valve Expansion Control Type:
					
					
						Thermostatic					
				 
							
					
						MRC:
						A designation of the evaporator temperature range at which the valve is designed to operate.AFKL
					 
					
						Valve Evaporator Tempurature Range Designation:
					
					
						Low					
				 
							
					
						MRC:
						An indication of whether or not a device is included that throttles or stops the flow of liquid,gas,and the like,through the valve when evaporator suction pressure reaches the maximum pressure setting.AFKM
					 
					
						Valve Pressure Limiting Device:
					
					
						Not included					
				 
							
					
						MRC:
						Indicates the type of transfer agent contained in the thermostatic bulb which reacts to temperature change.AFKQ
					 
					
						Bulb Media Type:
					
					
						Refrigerant 12					
				 
							
					
						MRC:
						The means utilized to hold the bulb in position.AFKR
					 
					
						Bulb Mounting Method:
					
					
						Well					
				 
							
					
						MRC:
						Indicates whether the equalizer location is internal,external,or both.AFKU
					 
					
						Valve Equalizer Location:
					
					
						Internal