MRC:
The name and number of components which make up the item.ALPC
Component And Quantity:
Oalarm unit chemical agent automatic alarm M42 /FSN6665-859-2215/, 1, battery dry /BA3517/, /FSN6135-450-3528/, 1, battery dry /BA3202/, /FSN6135-935-8738/, 4, detector unit chemical agent automatic alarm M43 /FSN6665-859-2201/, 1, installation kit chemical agent automatic alarm /for truck utility 1/4 ton/ /FSN6665-479-2716/, 1, mounting kit chemical agent automatic alarm M228 /high profile/ /FSN6665-859-2212/, 1, refill kit chemical agent automatic alarm M229 /FSN6665-859-2214/, 1
MRC:
Indicates the designed use of the item.ALXZ
Specific Usage Design:
Samples air continuously, which is automatically heated /if necessary/ filtered drawn into the detector cell where it passes through the electrolyte solution If v or g agent are present the galvanic voltage produced by the cell increases The change is amplified by the electronic module which sounds the detector horn and/or activates a flashing light applies power to the remote terminals and stops the pump motor the horn will continue to sound and/or the light flash until the detector is reset or disconnected by the operator The system is designed for manpack and vehicular application using dry cell battery for manpack and mounting kit and installation kit for 1/4 ton utility truck appl