Número de pieza
					Desmilitarización
					Vigencia
					UOM
					NIIN
				 
				
					
						Número de pieza:
						d26mr44a					
 
					
					
					
					
				 
			 
						
				
					NSN
				
				
					Número de acciones nacionales:
				
				
			 
			
				
					TXT
				
				
					Descripción:
				
				
					Electromagnetic Relay				
			 
			
				
				
					Código de nombre del artículo:
				
				
					32512				
			 
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						7.000 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						4.375 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						2.375 inches 					
				 
							
					
						MRC:
						The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.AFJN
					 
					
						Fragility Factor:
					
					
						Moderately rugged					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the alternating current.AJSS
					 
					
						Frequency In Hertz:
					
					
						60.0 					
				 
							
					
						MRC:
						The number of individual /not electrically connected/ windings.AKDX
					 
					
						Winding Quantity:
					
					
						1					
				 
							
					
						MRC:
						The purpose for which the item is designed.AKSL
					 
					
						Purpose For Which Designed:
					
					
						General					
				 
							
					
						MRC:
						The number of coils included on the item.APCN
					 
					
						Coil Quantity:
					
					
						1					
				 
							
					
						MRC:
						Indicates the type of duty provided.APNP
					 
					
						Duty Type:
					
					
						Continuous					
				 
							
					
						MRC:
						The means of quenching an arc.APNQ
					 
					
						Arc Quenching Method:
					
					
						Air					
				 
							
					
						MRC:
						Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.BBRG
					 
					
						Storage Type:
					
					
						General purpose warehouse					
				 
							
					
						MRC:
						The designation that identifies the schematic diagram of the electrical configuration of the main nonpile-up contacts including the number of poles or forms.CRNG
					 
					
						Nonpile-up Main Contact Arrangement:
					
					
						4 pole  single throw  normally open  momentary action and 4 pole  single throw  normally closed  momentary action					
				 
							
					
						MRC:
						The interval for which the item,by design,is purposely delayed between introduction of power into the energizing element and completion of travel of the contact carrier,and/or between interruption of the energizing power and return of the contact carrier to its normal de-energizing position.CRXH
					 
					
						Time Delay:
					
					
						0.006 seconds  fixed operate time and 0.013 seconds  fixed operate time					
				 
							
					
						MRC:
						The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.CSXF
					 
					
						Operating Voltage Rating And Type At Specificationified Temp:
					
					
						120.0 volts ac 25 degrees celsius all windings					
				 
							
					
						MRC:
						The amount of current the main contacts are rated to make or break at maximum rated voltage,with a specified load.CTDL
					 
					
						Main Contact Load Current Rating At Maximum Rated Voltage:
					
					
						10.0 amperes ac resistive load					
				 
							
					
						MRC:
						The highest voltage at which the main contacts are rated for normal operation,expressed in volts.CWAB
					 
					
						Main Contact Maximum Voltage Rating In Volts:
					
					
						5600.0 ac					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						10 screw all functions