Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
ch364-26vac60
NSN
Número de acciones nacionales:
TXT
Descripción:
Electronic Chopper
Código de nombre del artículo:
19759
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
8
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.938 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
1.010 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+85.0 degrees celsius
MRC:
Indicates the type of coil used.APAG
Coil Type:
Not isolated
MRC:
The designation that identifies the schematic diagram of the contact configuration.APFR
Contact Arrangement:
Double pole double throw
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
26.0 ac pounds per hour dry
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
30.0 ac volts
MRC:
Indicates the type of unit.APQB
Unit Type:
Electronic
MRC:
The number of complete cyclic changes,per unit of time,for which the output is rated.APTS
Output Frequency Rating:
60.0 hertz
MRC:
The output current rating at which the item is designed to operate.AQYD
Output Current Rating:
32.0 milliamperes
MRC:
Indicates the type of base furnished with the item.AWET
Base Type:
Standard base
MRC:
An indication of whether or not a hermetically sealed feature is provided.AXNN
Hermetically Sealed Feature:
Not provided
MRC:
The amount of input current for which the item is rated.AZSL
Input Current Rating:
32.0 milliamperes
MRC:
An indication of whether the drive voltage is the same as,or different from,the input voltage.BGRB
Drive Voltage Relationship To Input Voltage:
Equal
MRC:
The value,or range of values,for which the drive is rated.BGRC
Drive Voltage Rating:
26.0 ac pounds per hour wet
MRC:
An indication of whether the output voltage is the same as,or different from,the input voltage.BGRH
Output/input Voltage Relationship:
Unequal
MRC:
An indication of whether the item is designed to actuate /make/ a contact before or after the preceding contact deactuates /breaks/.BGRK
Contact Operation Sequence:
Makes before breaks
MRC:
The value,or range of values,for which the contact is rated.BGRL
Contact Voltage Rating:
1.500 dc pounds per hour with retaining chain
MRC:
The amount of current for which the contact is rated.BGRM
Contact Current Rating:
1.0 milliamperes
MRC:
The difference in phase between two alternating quantities having the same frequency,expressed in degrees.BGRN
Phase Angle In Deg:
30.0
MRC:
That portion of each driving cycle during which electrical continuity exists between the center contact and one stationary contact,expressed in degrees.BGRP
Dwell Time Rating In Deg:
170.0
MRC:
An indication of whether or not a feature for plug in mounting is provided.BGRS
Plug In Mounting Feature:
Provided
MRC:
The size designation of the mounting base as it is commercially known and/or identified.BGRT
Base Mounting Size Designation:
Octal tube base size
MRC:
An indication of the arrangement of the terminal pattern.BGRW
Terminal Pattern Arrangement:
Standard octal eight pin
MRC:
The style designation indicating the configuration that most nearly corresponds to the wiring of the base connection.BGRX
Base Connection Wiring Style:
8 pin standard octal tube
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
49956-321-1042+1 drawing (this is the basic governing drawing such as a contractor drawing original equipment manufacturer drawing etc excludes any specification, standard or other document that may be referenced in a basic governing drawing)