Número de pieza A-A-58049-II

Station Magnetic Inspection Unit

Precios y disponibilidad

Envíe este formulario para conocer los precios actuales y la disponibilidad de esta NSN.
Número de pieza:
Cantidad:
Dirección de correo electrónico:
Teléfono:
Referencia:
Compañía:
Nombre:

No compartimos ni vendemos su información a nadie.
Privacidad | Letra chica

All major credit cards accepted as well as gov. p-cards
Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
a-a-58049-ii
Desmilitarización:
No
Vigencia:
Unidad de medida:
NIIN:
010693670

Información de la pieza
Magnetized particles suspended inlight oil or water 6000 magnetizationac/dc, auto timer 0-1 sec demag ac auto timer 2-10 sec demag dc auto TIMER15-40 sec maximum capaci type 100 in Lg head to tail air supply reqd 80-100 psigpressure; duty cycle: 5 sec on 4 minOff and 10 sec on 3 min Off

NSN
Número de acciones nacionales:
6635-01-069-3670 6635010693670
TXT
Descripción:
Station Magnetic Inspection Unit
INC
INC
Código de nombre del artículo:
19005
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
5.0
MRC:
The maximum continuous demagnetizing current which must not be exceeded in order to avoid damage to the item,expressed in amperes.BCKD
Maximum Demagnetizing Current Rating In Amps:
6000.0
MRC:
The length of a straight line which passes through the center of a coil opening,and terminates at the circumference.BCKK
Err Default:
Err default
MRC:
An indication of whether or not an automatic cycle timer is included.BCKQ
Automatic Cycle Timer:
Included
MRC:
The working period under which the item is designed to operate.BCKR
Err Default:
Err default and err default
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
105.0 and 210.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The alpha-numeric designation that identifies the classification of the item according to the category of functions performed.FCLS
Functional Classification:
AA-8.12
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
0USED for rapid detection of discontinuities in ferromagnetic material which otherwise could not be seen by the inspector Longitudinal and transverse discontinuities may be found depending on the type of magnetization induced into the part
MRC:
Indicates the date the item was entered into mil-hdbk-300.NTRD
Entry Date:
80-11-01
MRC:
Literature and references available for information pertaining to the item.RDAL
Reference Data And Literature:
Af tO 33B2-21-1
MRC:
Indicates the relationship,such as construction,capabilities,and the like,of the item to a similar item.RTSE
Relationship To Similar Equipment:
6635-01-082-4064

Similar Station Magnetic Inspection Units

« Physical Properties Testing and Inspection Catálogo