Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Información de la pieza
Includes crank and calibrated scale coil turned on axis by crank
NSN
Número de acciones nacionales:
TXT
Descripción:
Radio Frequency Coil
Código de nombre del artículo:
06338
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
6.234 inches
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
44 single component single winding
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
2.375 inches single mounting facility single center group
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
2.188 inches single mounting facility single center group
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.125 inches single group
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
34.20 millihenries single component single winding
MRC:
Indicates the type of support on which the coil is wound.ACZP
Coil Form Type:
Hollow single component
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
4.781 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
2.156 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
2.000 inches
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
50.0 degrees celsius
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Open
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
4 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flange single group and unthreaded hole single group
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Electrical single component single winding and winding turns single component single winding
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.04030 inches american wire gage single component single winding
MRC:
The quality factor of an item with respect to a specified frequency for the rated inductance.CRHJ
Quality Factor:
125 single component single winding
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 tab solder lug