Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Desmilitarización:
Yes - DEMIL/MLI
Información de la pieza
Push to test button
NSN
Número de acciones nacionales:
TXT
Descripción:
Thermostatic Switch
Código de nombre del artículo:
00451
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Iiilength:
5.875 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
8.312 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.562 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
3.562 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
2.750 inches
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
0.406 inches
MRC:
The distance between mounting facility centers.AEJN
Distance Between Mounting Facility Centers:
2.750 inches
MRC:
A measurement of the longest dimension of a bulb.AEVU
Bulb Length:
3.688 inches
MRC:
The length of a straight line which passes through the center of the bulb,and terminates at the circumference.AEVV
Bulb Diameter:
0.688 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Used as the hot oil temperature switch on an eMD Model GMEQR8645-E6 and GMEQL8645-E6 diesel engines aboard 180 ft Class coast guard vessels
MRC:
Indicates the type of sensor or transducer used in the item to convert temperature changes to switch actuating force.AKBY
Tempurature Sensing Element Type:
Bulb
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flange and unthreaded hole
MRC:
An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.CQGB
Contact Action Stimulus:
Increase
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
Two position in-line
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
1 pole double throw both positions maintained
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Screw
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
9.6 amperes resistive load second voltage
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
16.0 amperes resistive load first voltage
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
16.0 amperes resistive load third voltage
MRC:
The adjustability of the contact.CTYC
Contact Adjustability:
Deactuation point adjustable and actuation point adjustable
MRC:
The minimum and maximum limits to which the contact(s) may be adjusted.CTYM
Contact Adjustment Range:
+210.00/+220.00 actuation point degrees fahrenheit and +210.00/+220.00 deactuation point degrees fahrenheit
MRC:
Indicates the type of device provided for manual adjustment of the contact(s).CTYS
Contact Adjustment Type:
External deactuation point screw and external actuation point screw
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
120.0 ac at sea level first voltage
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
120.0 dc at sea level second voltage
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
24.0 dc at sea level third voltage
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0 first voltage
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Gas or liquid
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular