Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
8493a-003
NSN
Número de acciones nacionales:
TXT
Descripción:
Fixed Attenuator
Código de nombre del artículo:
14224
MRC:
The primary application for which the item is designed.AAFS
Application Design:
Transmission line
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Any acceptable
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
ERR-090
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.562 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
0.500 inches
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.25 and 1.35
MRC:
A letter or group of letters used to designate the particular coaxial connector series.AHUC
Coaxial Connector Series Designation:
Sma
MRC:
The amount of electrical energy that can be dissipated.AJDB
Power Rating:
2.0 watts average and 100.0 watts peak
MRC:
The decrease in the strength of the radio frequency signals,expressed in decibels.AJDK
Rf Signal Attenuation In Decibels:
3.0
MRC:
The limits of permissible variation in the attenuation accuracy from the nominal value at a specified frequency rating or range,expressed in decibels.ASYN
Attenuation Accuracy In Decibels:
-0.30/+0.30
MRC:
The total variation in attenuation value across the operating frequency range,expressed in decibels.ASZL
Frequency Sensitivity Attenuation In Decibels:
0.001
MRC:
The specified variation of attenuation caused by a change of temperature,expressed in decibels.ASZM
Temperature Sensitivity Attenuation In Decibels:
0.0001
MRC:
The means of attaching the item.AXGY
Mounting Method:
Connector
MRC:
Indicates the type and number of terminal(s) for providing electrical connection.BBHS
Terminal Type And Quantity:
1 connector
MRC:
The minimum and maximum cyclic changes,per unit of time,for which an item is rated.BNGR
Frequency Range:
Between 0.000 hertz and 12.400 gigahertz
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Antennas waveguides and related equip