Número de pieza
					Desmilitarización
					Vigencia
					UOM
					NIIN
				 
				
					
						Número de pieza:
						8050000367					
 
					
					
					
					
				 
			 
						
				
					NSN
				
				
					Número de acciones nacionales:
				
				
			 
			
				
					TXT
				
				
					Descripción:
				
				
					Pre Wire Wound Variable Resistor				
			 
			
				
				
					Código de nombre del artículo:
				
				
					37408				
			 
										
					
						MRC:
						The number of individual elements.AAPN
					 
					
						Section Quantity:
					
					
						2					
				 
							
					
						MRC:
						An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
					 
					
						Reliability Indicator:
					
					
						Not established					
				 
							
					
						MRC:
						The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
					 
					
						Mounting Hole Diameter:
					
					
						Between 0.187 inches and 0.191 inches 					
				 
							
					
						MRC:
						A measurement of the longest dimension of the body,in distinction from width.ADAQ
					 
					
						Body Length:
					
					
						0.640 inches 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
					 
					
						Body Width:
					
					
						4.420 inches 					
				 
							
					
						MRC:
						A measurement from the bottom to the top of the body,in distinction from depth.ADAU
					 
					
						Body Height:
					
					
						4.420 inches 					
				 
							
					
						MRC:
						Indicates the type of facility or arrangement provided for moving the variable contact(s).AEFD
					 
					
						Actuator Type:
					
					
						Flush drive with slot-hole					
				 
							
					
						MRC:
						The maximum amount of turning force required to initiate the actuator movement.AEFK
					 
					
						Maximum Starting Torque:
					
					
						15.00 inch-ounces					
				 
							
					
						MRC:
						The maximum amount of force requred to maintain actuator movement.AEFL
					 
					
						Maximum Running Torque:
					
					
						15.00 inch-ounces					
				 
							
					
						MRC:
						The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.AFJN
					 
					
						Fragility Factor:
					
					
						Moderately rugged					
				 
							
					
						MRC:
						The number of mounting facilities provided.AKPV
					 
					
						Mounting Facility Quantity:
					
					
						4					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Unthreaded hole					
				 
							
					
						MRC:
						Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
					 
					
						Features Provided:
					
					
						Humidity proof					
				 
							
					
						MRC:
						A measure of the opposition to the flow of direct or alternating current per section.CQCC
					 
					
						Electrical Resistance Per Section:
					
					
						2.5 kilohms all sections					
				 
							
					
						MRC:
						The permissible range per section by which the actual value of resistance or voltage at any specified point may deviate from the theoretical value for the linear or nonlinear function,expressed as a minus and plus percent.CQFL
					 
					
						Function Conformity Tolerance Per Section:
					
					
						-1.00/+1.00 2ND section					
				 
							
					
						MRC:
						The ambient temperature at which the power dissipation of each section is derated to zero percent of the full rated power.CQGN
					 
					
						Ambient Tempurature In Deg Celsius Per Section At Zero Percent Rated Power:
					
					
						105.0 all sections					
				 
							
					
						MRC:
						The maximum amount of electrical energy that can be expended per section,expressed in watts.CRGD
					 
					
						Power Dissipation Rating Per Section In Watts:
					
					
						1.0 free air all sections					
				 
							
					
						MRC:
						The fidelity of the relationship between the actual function characteristics and the theoretical function per section.CRGM
					 
					
						Function Conformity Per Section:
					
					
						2ND section independent linearity					
				 
							
					
						MRC:
						The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.CRSS
					 
					
						Resistance Tolerance Per Section In Percent:
					
					
						-5.0/+5.0 all sections					
				 
							
					
						MRC:
						The specified mathematical relation per section between the terminal resistance,or output ratio,and the rotation of the actuator.CSBX
					 
					
						Function Characteristic Per Section:
					
					
						2ND section linear					
				 
							
					
						MRC:
						The ambient temperature,expressed in degrees celsius,of the medium surrounding each section at which it can be operated continuously at full rated power.CSDH
					 
					
						Ambient Tempurature In Deg Celsius Per Section At Full Rated Power:
					
					
						55.0 all sections					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						2 tab  solder lug and 4 turret