Número de pieza 7758B

Oscillograph

Precios y disponibilidad

Envíe este formulario para conocer los precios actuales y la disponibilidad de esta NSN.
Número de pieza:
Cantidad:
Dirección de correo electrónico:
Teléfono:
Referencia:
Compañía:
Nombre:

No compartimos ni vendemos su información a nadie.
Privacidad | Letra chica

All major credit cards accepted as well as gov. p-cards
Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
7758b
Desmilitarización:
No
Vigencia:
Unidad de medida:
NIIN:
010745706

Información de la pieza
Cabinet system

NSN
Número de acciones nacionales:
6625-01-074-5706 6625010745706
TXT
Descripción:
Oscillograph
INC
INC
Código de nombre del artículo:
18700
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
63.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
72.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
19.000 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Fixed
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
115.0 volts and 230.0 volts
MRC:
The means by which the item records information.ANBK
Recording Method:
Plastic coated heat sensitive
MRC:
The number of recording channels provided.BKBX
Recording Channel Quantity:
8
MRC:
The minimum and maximum values of the frequency range at which the item will record,expressed in hertz.BKBY
Recording Frequency Range In Hertz:
+0.0/+50.0
MRC:
The rated speed at which the chart is designed to operate.BKCB
Chart Speed:
0.5 millimeters per second and 1.0 millimeters per second and 2.5 millimeters per second and 5.0 millimeters per second and 10.0 millimeters per second and 25.0 millimeters per second and 50.0 millimeters per second and 100.0 millimeters per second and 200.0 millimeters per second
MRC:
An indication of whether or not an event marker(s) is provided.BKCD
Event Marker:
Provided
MRC:
The number of alternating current phases.FAAZ
Phase:
Single

Similar Oscillographes

« Electrical and Electronic Properties Measuring and Testing Instruments Catálogo
Comparar ahora»
Claro | Esconder