Número de pieza 61TYPE2

Electrical Meter Test Set

Precios y disponibilidad

Envíe este formulario para conocer los precios actuales y la disponibilidad de esta NSN.
Número de pieza:
Cantidad:
Dirección de correo electrónico:
Teléfono:
Referencia:
Compañía:
Nombre:

No compartimos ni vendemos su información a nadie.
Privacidad | Letra chica

All major credit cards accepted as well as gov. p-cards
Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
61type2
Desmilitarización:
No
Vigencia:
Unidad de medida:
NIIN:
007065091

Información de la pieza
Operating temperature 0 to 50 degrees c switch selectable scales +/- 0.1 accuracy low noise IEEE-488 interface

NSN
Número de acciones nacionales:
6625-00-706-5091 6625007065091
TXT
Descripción:
Electrical Meter Test Set
INC
INC
Código de nombre del artículo:
03636
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
17.000 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
23.750 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
100.0 volts or 110.0 volts or 115.0 volts or 120.0 volts or 200.0 volts or 220.0 volts or 230.0 volts or 240.0 volts
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Single item w/housing
MRC:
Indicates the type of test for which the item is designed.AQXY
Test Type For Which Designed:
Dc volts ac volts dc current ac current resistance
MRC:
The testing functions such as range,sensitivity,output,and the like,for which the item is designed.AQXZ
Operating Test Capability:
Dc VOLTS-20.0 mv to 1100.0 v ac VOLTS-20.0 mv to 1100 v dc CURRENT-200.0 ua to 2.0 a ac CURRENT-200 ua to 2.0 a resistance 1.0 ohm to 10 mohm
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Multimeter calibration
MRC:
A measurement from the bottom to the top of an object,in distinction from depth.HGTH
Height:
8.750 inches