Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
5900-1s1233425262403402
Información de la pieza
Measurement range continued: single indicator 17TH range M100.0/P100.0 volts dc
NSN
Número de acciones nacionales:
TXT
Descripción:
Multimeter
Código de nombre del artículo:
00794
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
14.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
16.750 inches
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.000 hertz and 60.000 hertz
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Rack mtg flange set 1
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Rack
MRC:
The minimum and maximum frequencies to which the item will respond without exceeding its accuracy rating.ANSY
Frequency Response Range:
+0.020/+300.000 kilohertz
MRC:
The source of power which provides the energy required for the operation of the item.AWZJ
Power Source:
External
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+0.1 kilohms single indicator 1ST range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+1.0 kilohms single indicator 2ND range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+1.0 kilovolts peak to peak single indicator 6TH range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+1.0 volts ac single indicator 11TH range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+10.0 kilohms single indicator 3RD range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+10.0 megohms single indicator 8TH range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+10.0 volts ac single indicator 12TH range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+10.0 ohms single indicator 10TH range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+100.0 kilohms single indicator 4TH range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+100.0 megohms single indicator 9TH range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+100.0 volts ac single indicator 13TH range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+1000.0 kilohms single indicator 5TH range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-0.1/+0.1 volts dc single indicator 14TH range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-1.0/+1.0 kilovolts dc single indicator 7TH range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-1.0/+1.0 volts dc single indicator 15TH range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-10.0/+10.0 volts dc single indicator 16TH range
MRC:
The means provided for selecting a scale.BLSB
Scale Selection Method:
Switch
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Self-illumination facility
MRC:
The means provided for electrical connection to a circuit and the number of each type of connection.CTTD
Circuit Attachment Method And Quantity:
4 connector receptacle
MRC:
The value(s) of root mean square or direct current potential which must be applied to the item for operation,expressed in volts.CTWN
Operating Voltage Rating In Volts:
Between 100.0 ac and 240.0 ac
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rack