Número de pieza
					Desmilitarización
					Vigencia
					UOM
					NIIN
				 
				
					
					
						Desmilitarización:
						Yes - DEMIL/MLI					 
					
					
					
				 
			 
							
					
						Información de la pieza
						Front panel ac on control front panel type n rf input & output rear panel ac line connector unit will withstand 13DBM input signal 1V rms for all output load conditions forced air cooling system input vswr 1.8: 1 max output vswr 2.5: 1 max noise figure 12DB max
					 
				 
						
				
					NSN
				
				
					Número de acciones nacionales:
				
				
			 
			
				
					TXT
				
				
					Descripción:
				
				
					Radio Frequency Amplifier				
			 
			
				
				
					Código de nombre del artículo:
				
				
					00446				
			 
							
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						19.750 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						8.500 inches 					
				 
							
					
						MRC:
						An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
					 
					
						Overall Width:
					
					
						15.500 inches 					
				 
							
					
						MRC:
						The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
					 
					
						Operating Tempurature Range:
					
					
						+0.0/+45.0 degrees celsius					
				 
							
					
						MRC:
						A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
					 
					
						Average Life Measurement:
					
					
						Not rated					
				 
							
					
						MRC:
						The national stock number or the identification information of the end equipment for which the item is a part.AGAV
					 
					
						End Application:
					
					
						5820-01-070-7911					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
					 
					
						Basic Shape Style:
					
					
						Rectangular or square					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Encased					
				 
							
					
						MRC:
						The installation for which the item is designed.AMQY
					 
					
						Installation Design:
					
					
						Rack					
				 
							
					
						MRC:
						Indicates the type of circuit construction provided in the item.BHSX
					 
					
						Circuit Construction Type:
					
					
						Solid state					
				 
							
					
						MRC:
						The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
					 
					
						Frequency Per Channel:
					
					
						1.5 megahertz  operating channel and 400.0 megahertz  operating channel					
				 
							
					
						MRC:
						The rated average power for each channel.BHTJ
					 
					
						Average Power Rating Per Channel:
					
					
						50.0 watts output					
				 
							
					
						MRC:
						The increase in energy from the input to the output.BHTL
					 
					
						Overall Gain:
					
					
						50.0 decibels					
				 
							
					
						MRC:
						The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
					 
					
						Impedance Rating Per Channel:
					
					
						50.000 ohms output channel ERR-100					
				 
							
					
						MRC:
						The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
					 
					
						Impedance Rating Per Channel:
					
					
						50.000 ohms input channel ERR-100					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the operating alternating current.BJBQ
					 
					
						Operating Ac Frequency In Hertz:
					
					
						50.0  1ST voltage and 60.0  1ST voltage					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the operating alternating current.BJBQ
					 
					
						Operating Ac Frequency In Hertz:
					
					
						50.0  2ND voltage and 60.0  2ND voltage					
				 
							
					
						MRC:
						The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
					 
					
						External Ac Operating Voltage In Volts:
					
					
						115.0  1ST voltage					
				 
							
					
						MRC:
						The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
					 
					
						External Ac Operating Voltage In Volts:
					
					
						230.0  2ND voltage					
				 
							
					
						MRC:
						The number of alternating current phases.FAAZ
					 
					
						Phase:
					
					
						Single