Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Desmilitarización:
Yes - DEMIL/MLI
NSN
Número de acciones nacionales:
TXT
Descripción:
Voltmeter
Código de nombre del artículo:
16449
MRC:
The type of electrical circuit in which the item is designed to be used.AACT
Circuit Current For Which Designed:
Ac
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.430 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
3.500 inches
MRC:
The length of a straight line which passes through the center of a mounting bolt circle,and terminates at the circumference.AFFL
Mounting Bolt Circle Diameter:
3.124 inches
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Panel
MRC:
The style designation indicating the configuration that most nearly corresponds to the arrangement of the mounting.ANRL
Mounting Arrangement Style:
Three hole/stud bolt circle
MRC:
The minimum and maximum frequencies to which the item will respond without exceeding its accuracy rating.ANSY
Frequency Response Range:
+0.000/+400.000 hertz
MRC:
The hue or tint of the dial scale marking(s).APMM
Dial Scale Marking Color:
Black all indicators single range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-2.0/+2.0 at full scale all indicators all ranges
MRC:
A measurement between the mounting flange and the extremity of the meter, indistinction from height.APST
Meter Depth Behind Mounting Flange:
2.031 inches
MRC:
The length of a straight line which passes through the center of the meter body behind the mounting flange, and terminates at the circumference.APSW
Meter Body Diameter Behind Mounting Flange:
2.690 inches
MRC:
Indicates the type of movement provided.AQEC
Movement Type:
Moving iron vane
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+150.0 volts ac 1ST indicator single range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+300.0 volts ac 2ND indicator single range
MRC:
The means provided for electrical connection to a circuit and the number of each type of connection.CTTD
Circuit Attachment Method And Quantity:
3 solder stud
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
C1 round flush mtg
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Round flush mtg