Número de pieza 432A-902

Power Factor Meter

Precios y disponibilidad

Envíe este formulario para conocer los precios actuales y la disponibilidad de esta NSN.
Número de pieza:
Cantidad:
Dirección de correo electrónico:
Teléfono:
Referencia:
Compañía:
Nombre:

No compartimos ni vendemos su información a nadie.
Privacidad | Letra chica

All major credit cards accepted as well as gov. p-cards
Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
432a-902
Desmilitarización:
No
Vigencia:
Unidad de medida:
NIIN:
011437304
NSN
Número de acciones nacionales:
6625-01-143-7304 6625011437304
TXT
Descripción:
Power Factor Meter
INC
INC
Código de nombre del artículo:
16452
MRC:
The type of electrical circuit in which the item is designed to be used.AACT
Circuit Current For Which Designed:
Ac
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
279.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
130.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
155.000 inches
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
144 single indicator all ranges
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
50.0 hertz
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-0.002/+0.002 at full scale single indicator all ranges
MRC:
Indicates the type of graduations provided on the scale.BHDC
Scale Graduation Type:
Nonlinear single indicator all ranges
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
-20.0/+10.0 milliwatts single indicator 1ST range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.001/+0.010 milliwatts single indicator 2ND range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+10.0/+300.0 decibels above or below one milliwatt single indicator 3RD range
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Portable
MRC:
The means provided for electrical connection to a circuit and the number of each type of connection.CTTD
Circuit Attachment Method And Quantity:
2 connector plug
MRC:
The value(s) of root mean square or direct current potential which must be applied to the item for operation,expressed in volts.CTWN
Operating Voltage Rating In Volts:
220.0 ac
MRC:
The number of alternating current phases.FAAZ
Phase:
Single

Similar Power Factor Meters

« Electrical and Electronic Properties Measuring and Testing Instruments Catálogo
Comparar ahora»
Claro | Esconder