Número de pieza 388-07

Signal Data Converter

Precios y disponibilidad

Envíe este formulario para conocer los precios actuales y la disponibilidad de esta NSN.
Número de pieza:
Cantidad:
Dirección de correo electrónico:
Teléfono:
Referencia:
Compañía:
Nombre:

No compartimos ni vendemos su información a nadie.
Privacidad | Letra chica

All major credit cards accepted as well as gov. p-cards
Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
388-07
Desmilitarización:
Yes - DEMIL/MLI
Vigencia:
Unidad de medida:
NIIN:
015234569

Información de la pieza
If to tape/baseband converter

NSN
Número de acciones nacionales:
5895-01-523-4569 5895015234569
TXT
Descripción:
Signal Data Converter
INC
INC
Código de nombre del artículo:
00441
INC
COM
Conformidad:
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+0.0/+40.0 degrees celsius
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Not rated
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The means by which the item is operated or controlled.ALBM
Operating Control Method:
Automatic
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Rack
MRC:
Indicates the type of control.AQZF
Control Type:
Remote
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
10.0 megahertz 4TH input channel ERR-100 and 250.0 megahertz 4TH input channel ERR-100
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
160.0 megahertz 3RD input channel ERR-100
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
1.1 megahertz 1ST output channel ERR-100
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
4.3 megahertz 4TH output channel ERR-100
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
50.0 megahertz 5TH input channel ERR-100
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
70.0 megahertz 2ND input channel ERR-100
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
2.2 megahertz 2ND output channel ERR-100
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
21.4 megahertz 1ST input channel ERR-100
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
3.2 megahertz 3RD output channel ERR-100
MRC:
Indicates the type of frequency adjustment included in the item.BHTD
Frequency Adjustment Type:
Stepped
MRC:
The frequency of each step.BHTF
Individual Step Frequency:
5000.0 kilohertz and 1.0 kilohertz
MRC:
The amount of allowable variation relative to a specified frequency level,expressed in decibels.BHTG
Variation Frequency Rating In Decibels:
-0.5 and 0.5
MRC:
The decrease in strength of an electrical impulse,expressed in decibels.BHTH
Attenuation In Decibels:
14.0
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
50.000 ohms operating channel
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
1ST input channel pulse ERR-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
1ST output channel pulse ERR-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
2ND input channel pulse ERR-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
2ND output channel pulse ERR-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
3RD output channel pulse ERR-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
3RD input channel pulse ERR-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
4TH input channel pulse ERR-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
4TH output channel pulse ERR-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
5TH input channel pulse ERR-100
MRC:
Indicates the type of connection and its location on the item.BJBP
Connection Type And Location:
Connector plug rear
MRC:
Indicates the type and number of contact(s) included in the connection.BJBW
Connection Contact Type And Quantity:
9 connector plug external
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
RS-233 control group delay equalization; compact half-rack package input level range negative 70 dbm to 0 dbm power 90-240 vac 47-420 hz 45 watts max weight 8 lb warran type 1 year
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Used to convert if to tape and record a/d signals