Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
360-184-01
Desmilitarización:
Yes - DEMIL/MLI
Información de la pieza
Arbitray generator 33250A
NSN
Número de acciones nacionales:
TXT
Descripción:
Electronic Te Function Generator
Código de nombre del artículo:
47471
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
348.0 millimeters
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
89.0 millimeters
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
213.0 millimeters
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+0.0/+55.0 degrees celsius
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Not rated
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Adavanced digital test syste (adts)
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The means by which the item is operated or controlled.ALBM
Operating Control Method:
Automatic or manual
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Rack
MRC:
Indicates the type of control.AQZF
Control Type:
Local or remote
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
1ST output channel synchro ERR-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
2ND output channel analog voltage ERR-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
2ND output channel pulse ERR-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
2ND output channel pulse amplitude ERR-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
2ND output channel sweep ERR-100
MRC:
The physical configuration of the output wave.BJBJ
Output Wave Shape:
Pulse variable width and sine and square
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
50.0 1ST voltage and 60.0 1ST voltage
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
50.0 2ND voltage and 400.0 2ND voltage
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
100.0 1ST voltage and 240.0 1ST voltage
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
100.0 2ND voltage and 127.0 2ND voltage
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
80MHZ sine and squarewave outputs 50MHZ pulse waveforms with variable rise and fall times 12BIT 200MSA/S 64K point deep arbitrary waveform color graphical display waveform types are: sine square pulse ramp noise sinx over x exponential rise and fall cardiac dc volts warmup time 1 hour weight 4.6 kg dimensions 213MM wide 89MM high 348MM deep this is a modified agilent 33250A with option 1CM (rackmount kit) and option aba (english manual