Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
3266w-1-202lf
NSN
Número de acciones nacionales:
TXT
Descripción:
Nonwire Wound Variable Resistor
Código de nombre del artículo:
37405
MRC:
The number of individual elements.AAPN
Section Quantity:
1
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Rectangular
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
4.78 millimeters
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
1.78 millimeters
MRC:
A measurement of the longest dimension of the shaft,in distinction from width.ABXF
Shaft Length:
1.0 millimeters
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
6.7 millimeters
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
4.5 millimeters
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
7.24 millimeters
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the shaft.AEDX
Shaft Style:
Round slotted
MRC:
Indicates the type of facility or arrangement provided for moving the variable contact(s).AEFD
Actuator Type:
Single shaft
MRC:
The center to center distance between terminals.AEHT
Center To Center Distance Between Terminals:
5.08 millimeters
MRC:
The position of the terminal/s/ for making connection to an item.APXH
Terminal Location:
Rear end
MRC:
The means of attaching the item.AXGY
Mounting Method:
Terminal
MRC:
The center to center distance between the rows of terminals.AYQR
Center To Center Distance Between Terminal Rows:
2.54 millimeters
MRC:
A measure of the opposition to the flow of direct or alternating current per section.CQCC
Electrical Resistance Per Section:
2.0 percent rated amperes c and better flooring
MRC:
The center to center distance between the center terminal and the outside terminal.CQCM
Center To Center Distance Between Center Terminal And Outside Terminal:
2.54 major inches
MRC:
The maximum amount of electrical energy that can be expended per section,expressed in watts.CRGD
Power Dissipation Rating Per Section In Watts:
0.25 7TH secondary quality
MRC:
The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.CRSS
Resistance Tolerance Per Section In Percent:
-10.0/+10.0 single section
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
3 pin