Número de pieza 315

Psychrometer

Precios y disponibilidad

Envíe este formulario para conocer los precios actuales y la disponibilidad de esta NSN.
Número de pieza:
Cantidad:
Dirección de correo electrónico:
Teléfono:
Referencia:
Compañía:
Nombre:

No compartimos ni vendemos su información a nadie.
Privacidad | Letra chica

All major credit cards accepted as well as gov. p-cards
Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
315
Desmilitarización:
No
Vigencia:
Unidad de medida:
NIIN:
005301094
NSN
Número de acciones nacionales:
6685-00-530-1094 6685005301094
TXT
Descripción:
Psychrometer
INC
INC
Código de nombre del artículo:
09725
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
11.875 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
0.938 inches
MRC:
Indicates the type of handle designed to be attached to or through an item for the purpose of opening,lifting,closing,or the like.ADQF
Handle Type:
Swivel
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-35.0/+115.0 degrees fahrenheit
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-35.0 to 115.0 degrees fahrenheit
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
Wicks 3
MRC:
The interval/s/ as indicated by the markings on the item.AWEC
Graduation Interval:
10.0 deg
MRC:
An indication of whether or not a magnifying lens is included.BBST
Magnifying Lens:
Included
MRC:
The degree of conformity of a measurement to a standard or true value for which the calibration is rated.BDHW
Calibration Accuracy Rating:
Porm 0.4 f above 32 deg porm 0.6 f P32 degrees to 0 deg porm 0.8 f below 0 deg
MRC:
Indicates the type of circulation provided.BHGS
Circulation Type:
Forced
MRC:
The means used to provide circulation.BHGT
Circulation Method:
Hand sling
MRC:
The number of thermometers on the item.BHGW
Thermometer Quantity:
2
MRC:
An indication of whether or not an engraved thermometer stem is included.BHGX
Engraved Thermometer Stem:
Not included
MRC:
Indicates the type of substance with which the thermometer is filled.BHGY
Thermometer Filling Type:
Mercury
MRC:
The means of attaching the thermometer.BHGZ
Thermometer Mounting Method:
Backplate
MRC:
The element,compound,or mixture of which the thermometer mounting is fabricated,excluding any surface treatment.BHHB
Thermometer Mounting Material:
Aluminum
MRC:
The element,compound,or mixture of which the cistern is fabricated,excluding any surface treatment.BHHD
Cistern Material:
Any acceptable
MRC:
An indication of whether or not a sling handle is included.BHHF
Sling Handle:
Included
MRC:
An indication of whether or not a mounting shelter is included.BHHG
Mounting Shelter:
Not included
MRC:
An indication of whether or not tables are provided on the mounting panel.BHHH
Mounting Panel Tables:
Not provided
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Wood
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Wood