Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
309-23033-01
NSN
Número de acciones nacionales:
TXT
Descripción:
Radio Frequency Interfere Filter
Código de nombre del artículo:
00765
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.950 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.150 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
2.300 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
1.600 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
1.900 inches
MRC:
The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
Source Impedance Rating Per Function:
50.0 ohms 1ST radio interference
MRC:
The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
Source Impedance Rating Per Function:
50.0 ohms 2ND radio interference
MRC:
The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
Source Impedance Rating Per Function:
50.0 ohms 3RD radio interference
MRC:
The total opposition per function,presented by a load to the output terminals of an item.AHAS
Load Impedance Per Function:
50.0 ohms 1ST radio interference
MRC:
The total opposition per function,presented by a load to the output terminals of an item.AHAS
Load Impedance Per Function:
50.0 ohms 3RD radio interference
MRC:
The total opposition per function,presented by a load to the output terminals of an item.AHAS
Load Impedance Per Function:
50.0 ohms 2ND radio interference
MRC:
The cycles per second /hertz/ of the power line alternating current.AHBB
Power Line Frequency Rating Per Function In Hertz:
60.0 1ST radio interference
MRC:
The cycles per second /hertz/ of the power line alternating current.AHBB
Power Line Frequency Rating Per Function In Hertz:
60.0 2ND radio interference
MRC:
The cycles per second /hertz/ of the power line alternating current.AHBB
Power Line Frequency Rating Per Function In Hertz:
60.0 3RD radio interference
MRC:
The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
Operating Current Rating Per Function In Amps:
1.0 1ST radio interference
MRC:
The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
Operating Current Rating Per Function In Amps:
1.0 3RD radio interference
MRC:
The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
Operating Current Rating Per Function In Amps:
1.0 2ND radio interference
MRC:
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter on the mounting facility.AKEJ
Mounting Facility Screw Thread Series Designator:
Unc
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Hermetically sealed
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 threaded hole
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
3 tab solder lug output 2ND function
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
3 turret input 1ST function
MRC:
The level of electrical potential and type of current,per function,for which the item is designed.CQGC
Operating Voltage Rating And Type Per Function:
115.0 volts ac 1ST radio interference 1ST function
MRC:
The level of electrical potential and type of current,per function,for which the item is designed.CQGC
Operating Voltage Rating And Type Per Function:
115.0 volts ac 2ND radio interference 2ND function
MRC:
The level of electrical potential and type of current,per function,for which the item is designed.CQGC
Operating Voltage Rating And Type Per Function:
115.0 volts ac 3RD radio interference 3RD function
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.112 inches
MRC:
The chemical compound or mechanical mixture properties of which the body is fabricated.CQRG
Body Material:
Metal
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular terminal/terminals on two surfaces