Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Desmilitarización:
Yes - DEMIL/MLI
Unidad de medida:
* special requirements. EA
Información de la pieza
Max weight 1 lb
NSN
Número de acciones nacionales:
TXT
Descripción:
Radio Frequency Monitor
Código de nombre del artículo:
00771
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.940 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.200 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.800 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-20.0/+70.0 degrees celsius
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Not rated
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
10000.0 feet
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The means by which the item is operated or controlled.ALBM
Operating Control Method:
Automatic
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Mechanical
MRC:
Indicates the type of control.AQZF
Control Type:
Remote
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
1350.0 megahertz operating channel and 1850.0 megahertz operating channel
MRC:
The rated average power for each channel.BHTJ
Average Power Rating Per Channel:
40.0 watts input
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
50.000 ohms output channel ERR-100
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
50.000 ohms input channel ERR-100
MRC:
Indicates the type of connection and its location on the item.BJBP
Connection Type And Location:
Receptacle coaxial left side and integral cable w/power plug right side and receptacle coaxial right side
MRC:
Indicates the type and number of contact(s) included in the connection.BJBW
Connection Contact Type And Quantity:
1 integral cable w/power plug external and 2 receptacle coaxial external