Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Desmilitarización:
Yes - DEMIL/MLI
Información de la pieza
Tubing wall construction can also be laminated
NSN
Número de acciones nacionales:
TXT
Descripción:
Waveguide Assembly
Código de nombre del artículo:
00305
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Internal rectangular external rectangular
MRC:
The angular measurement by which one part/section of a rigid item deviates from a straight line projection of an adjacent part/section,expressed in degrees.ACJL
Bend Angle In Deg:
45.0 third bend h-plane
MRC:
The angular measurement by which one part/section of a rigid item deviates from a straight line projection of an adjacent part/section,expressed in degrees.ACJL
Bend Angle In Deg:
45.0 second bend h-plane
MRC:
The angular measurement by which one part/section of a rigid item deviates from a straight line projection of an adjacent part/section,expressed in degrees.ACJL
Bend Angle In Deg:
90.0 first bend e-plane
MRC:
The style designation indicating the configuration that most nearly corresponds to the construction of the tubing wall.AHRV
Tubing Wall Construction Style:
Seamless single tubing segment
MRC:
The number of flanges provided with the item.AHSF
Flange Quantity:
2
Flange Inside Width:
0.978 inches first flange and 0.990 inches first flange
Flange Inside Width:
1.003 inches second flange and 1.006 inches second flange
Flange Inside Height:
0.433 inches first flange and 0.443 inches first flange
Flange Inside Height:
0.503 inches second flange and 0.506 inches second flange
Flange Outside Width:
1.610 inches second flange and 1.640 inches second flange
Flange Outside Width:
2.500 inches first flange
Flange Outside Height:
1.610 inches second flange and 1.640 inches second flange
Flange Outside Height:
1.750 inches first flange
MRC:
A measurement between specified points on the flange,in distinction from height.AHTD
Flange Depth:
0.422 inches second flange and 0.453 inches second flange
MRC:
A measurement between specified points on the flange,in distinction from height.AHTD
Flange Depth:
0.656 inches first flange
MRC:
The length of a straight line which passes through the center of a flange connecting hole,and terminates at the circumference.AHTN
Flange Connecting Hole Diameter:
0.166 inches first flange single connection facility and 0.172 inches first flange single connection facility
MRC:
The length of a straight line which passes through the center of a flange connecting hole,and terminates at the circumference.AHTN
Flange Connecting Hole Diameter:
0.169 inches second flange single connection facility and 0.172 inches second flange single connection facility
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.10
MRC:
The difference in the amount of energy available before and after the insertion of an apparatus in a transmission system,expressed in decibels.AHTX
Insertion Loss In Decibels:
0.12
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
10.0 pounds per square inch gage
Waveguide Outside Width:
Between 0.996 inches and 1.004 inches
Waveguide Inside Width:
Between 0.896 inches and 0.904 inches
Waveguide Inside Height:
Between 0.396 inches and 0.404 inches
Waveguide Outside Height:
Between 0.496 inches and 0.504 inches
MRC:
The type and number of facilities by which the flange is connected.CSQT
Flange Connecting Facility And Quantity:
4 unthreaded hole second flange single connection facility
MRC:
The type and number of facilities by which the flange is connected.CSQT
Flange Connecting Facility And Quantity:
8 unthreaded hole first flange single connection facility
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the flange.CTCJ
Flange Style:
Contact type first flange
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the flange.CTCJ
Flange Style:
Cover type second flange
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Rigid single tubing segment
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Aluminum alloy all flange
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Aluminum alloy single tubing segment
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Oxide film all tubing segment outside surfaces
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Oxide film single tubing segment inside surfaces