Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
284-2216
Información de la pieza
Critical appl-trans radar set AN/TPS-32; tac air opn cntl AN/TYQ-2
NSN
Número de acciones nacionales:
TXT
Descripción:
Multimeter
Código de nombre del artículo:
00794
MRC:
The type of electrical circuit in which the item is designed to be used.AACT
Circuit Current For Which Designed:
Dc
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
1.800 inches
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
7.100 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.400 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Cold resistant and heat resistant and shock resistant and vibration resistant and water resistant
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Manual 1; test lead 2; 9 v btry 1; oper card 1; fuse 1; cal certificate 1
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Digital display
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Hand held
MRC:
The minimum and maximum frequencies to which the item will respond without exceeding its accuracy rating.ANSY
Frequency Response Range:
+48.000/+450.000 hertz
MRC:
The hue or tint of the background.AQFY
Background Color:
Gray single indicator all ranges
MRC:
The source of power which provides the energy required for the operation of the item.AWZJ
Power Source:
Internal
MRC:
Indicates the type of display provided.BFQN
Display Type:
Liquid crystal
MRC:
The number of digits displayed.BFQP
Display Digit Quantity:
3-1/2
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+1000.0 volts dc single indicator 16TH range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+2.0 kilohms single indicator 1ST range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+2.0 milliamperes, dc single indicator 7TH range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+2.0 milliamperes, ac single indicator 4TH range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+2.0 volts ac single indicator 12TH range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+2.0 volts dc single indicator 15TH range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+20.0 megohms single indicator 3RD range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+20.0 milliamperes, ac single indicator 5TH range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+200.0 millivolts dc single indicator 10TH range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+200.0 ohms single indicator 11TH range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+200.0 millivolts ac single indicator 9TH range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+200.0 volts ac single indicator 13TH range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+2000.0 kilohms single indicator 2ND range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+2000.0 milliamperes, ac single indicator 6TH range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+2000.0 milliamperes, dc single indicator 8TH range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+750.0 volts ac single indicator 14TH range
MRC:
The means provided for selecting a scale.BLSB
Scale Selection Method:
Switch and terminal
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Electrical overload protection and internal battery accommodation and portable and warning feature
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Feat
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Poam 5.0 pct of reading plus 5 digits single indicator 9TH range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 0.1 pct of reading plus 1 digit single indicator 10TH range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 0.1 pct of reading plus 1 digit single indicator 15TH range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 0.1 pct of reading plus 1 digit single indicator 16TH range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 0.1 pct of reading plus 1 digit single indicator 1ST range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 0.15 pct of reading plus 1 digit single indicator 2ND range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 0.2 pct of reading plus 3 digits single indicator 11TH range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 0.75 pct of reading plus 1 digit single indicator 7TH range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 0.75 pct of reading plus 1 digit single indicator 8TH range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 1.0 pct of reading plus 2 digits single indicator 14TH range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 1.5 pct of reading plus 2 digits single indicator 5TH range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 1.5 pct of reading plus 2 digits single indicator 6TH range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 1.5 pct of reading plus 3 digits single indicator 13TH range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 2.0 pct of reading plus 1 digit single indicator 3RD range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 3.0 pct of reading plus 2 digits single indicator 4TH range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 5.0 pct of reading plus 5 digits single indicator 12TH range
MRC:
The hue or tint of the display.CTQH
Display Color:
Black single indicator all ranges
MRC:
The means provided for electrical connection to a circuit and the number of each type of connection.CTTD
Circuit Attachment Method And Quantity:
3 wire lead
MRC:
The value(s) of root mean square or direct current potential which must be applied to the item for operation,expressed in volts.CTWN
Operating Voltage Rating In Volts:
9.0 dc
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic
MRC:
An indication of the nuclear hardness criticality of the item.NHCF
Nuclear Hardness Critical Feature:
Nonhardened
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Hand-held
MRC:
A measurement of volume taken by multiplying the length by the width by the height of the unit of issue and rendered in cubic units.SUCB
Unit Of Issue Cube:
0.025 cubic feet
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Visual and audible continuity peak-hold level detection conductance; diode test
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Test set elect Equip