Número de pieza
					Desmilitarización
					Vigencia
					UOM
					NIIN
				 
				
			 
						
				
					NSN
				
				
					Número de acciones nacionales:
				
				
			 
			
				
					TXT
				
				
					Descripción:
				
				
					Flow Switch				
			 
			
				
				
					Código de nombre del artículo:
				
				
					36841				
			 
										
					
						MRC:
						The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.ABFE
					 
					
						Hazardous Locations/environmental Protection:
					
					
						Vibration resistant					
				 
							
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						3.281 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						4.500 inches 					
				 
							
					
						MRC:
						The temperature at which the item operates.AWTN
					 
					
						Operating Tempurature Rating:
					
					
						Between -65.0 degrees fahrenheit and 250.0 degrees fahrenheit 					
				 
							
					
						MRC:
						The means of attaching the item.AXGY
					 
					
						Mounting Method:
					
					
						Line and threaded bushing					
				 
							
					
						MRC:
						Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
					 
					
						Features Provided:
					
					
						Hermetically sealed case					
				 
							
					
						MRC:
						The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
					 
					
						Thready Qty Per Inch (tpi):
					
					
						14 single threaded bushing					
				 
							
					
						MRC:
						An indication of whether the initial action of the contacts occurs as the result of an increase or decrease in stimulus.CQGB
					 
					
						Contact Action Stimulus:
					
					
						Decrease					
				 
							
					
						MRC:
						A designation that is used for the purpose of general identification of the thread.CQJX
					 
					
						Thread Size:
					
					
						0.500 inches single threaded bushing					
				 
							
					
						MRC:
						The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
					 
					
						Nonpile-up Contact Arrangement:
					
					
						1 pole  single throw  normally closed  momentary action					
				 
							
					
						MRC:
						Indicates the type of terminal for providing electrical connection to the item.CSCF
					 
					
						Terminal Type:
					
					
						Wire lead					
				 
							
					
						MRC:
						The amount of current that the contacts are rated to make or break with a specified load.CTHF
					 
					
						Contact Load Current Rating:
					
					
						0.5 amperes resistive load second voltage					
				 
							
					
						MRC:
						The amount of current that the contacts are rated to make or break with a specified load.CTHF
					 
					
						Contact Load Current Rating:
					
					
						45.4 milliamperes resistive load first voltage					
				 
							
					
						MRC:
						The adjustability of the contact.CTYC
					 
					
						Contact Adjustability:
					
					
						Deactuation point not adjustable					
				 
							
					
						MRC:
						The rating of the stimulus required to actuate and/or deactuate the contact(s).CTYX
					 
					
						Contact Stimulus Rating:
					
					
						10.50 deactuation point  gallons per minute					
				 
							
					
						MRC:
						The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
					 
					
						Contact Voltage Rating In Volts:
					
					
						220.0 ac at sea level first voltage					
				 
							
					
						MRC:
						The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
					 
					
						Contact Voltage Rating In Volts:
					
					
						32.0 dc at sea level second voltage					
				 
							
					
						MRC:
						The type of media for which the item is designed.MEDA
					 
					
						Media For Which Designed:
					
					
						Liquid					
				 
							
					
						MRC:
						A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
					 
					
						Thread Series Designator:
					
					
						Npt single threaded bushing