Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
1801-3800-3
Desmilitarización:
Yes - DEMIL/MLI
NSN
Número de acciones nacionales:
TXT
Descripción:
Electronic Control Amplifier
Código de nombre del artículo:
00096
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.625 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
2.000 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Cylindrical
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Mechanical
MRC:
The rated average power for each channel.BHTJ
Average Power Rating Per Channel:
16.0 watts output
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
30.000 ohms output channel ERR-100
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
40.000 kilohms 1ST input channel ERR-100
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
80.000 kilohms 2ND input channel ERR-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
1ST input channel error ERR-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
2ND input channel error ERR-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
Output channel servo ERR-100
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
400.0 single voltage
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
28.0 single voltage
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
115.0 single voltage
MRC:
The number of alternating current phases.FAAZ
Phase:
Three