Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
17g450398-1
Información de la pieza
Hydraulic test bench
NSN
Número de acciones nacionales:
TXT
Descripción:
Hydraulic System Comp Test Stand
Código de nombre del artículo:
11017
MRC:
The amount of hydraulic fluid required to operate the item.AAYJ
Hydraulic Fluid Flow Rate:
5.0 gallons per minute
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
Indicates the designed use of the item.ALBY
Usage Design:
Aircraft hydraulic system
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Fixed
MRC:
The source of power which drives the item.ATJK
Power Source:
Electric motor
MRC:
An indication of whether or not an accumulator is included.AYJM
Accumulator:
Not included
MRC:
The pressure at which an item is designed to operate.BGST
Pressure Rating:
Between 4000.0 pounds per square inch and 6000.0 pounds per square inch
MRC:
An indication of whether or not a design feature for testing engine driven hydraulic pumps is included.CGYK
Engine Driven Hydraulic Pump Testing Design Feature:
Not included
MRC:
An indication of whether or not a pressure manifold subcircuit(s) is included.CGYM
Pressure Manifold Subcircuit:
Not included
MRC:
An indication of whether or not a filtering system is included.CHGQ
Filtering System:
Not included
MRC:
An indication of whether or not a pressure and suction hose are included.CHGR
Pressure/suction Hose:
Not included
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
115.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Dual system manually operated stationary test bench with a stainless steel cabinet uses depot 4000 psi AND6000 psi hydraulic manifolds for hydraulic pressure and flow includes all necessary hyrdaulic filters regulators pressure gauges flow meters reliefvalves and control valves all pressure gauges and flow meters have analog and digital readouts includes built-inelectrical dc power supply and duel servo controlers with lvt feedback hydraulic fluid per MIL-H-83282; fluid temp +50 to 275 degrees f flow vs pressure: 5 gpm at 6000 psi 30 gpm at 4000 psi 60 gpm at 500 psi height 72 inches width 120 inches depth 49 inches
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Used to functionally test all C-17A hyrdaulic lru's except pumps
MRC:
Literature and references available for information pertaining to the item.RDAL
Reference Data And Literature:
Serd number 450398