Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
168331-1
Unidad de medida:
No qup EA
NSN
Número de acciones nacionales:
TXT
Descripción:
Electrical Dummy Load
Código de nombre del artículo:
00335
MRC:
The amount of coolant necessary to maintain the required operating temperature of the item.AAXT
Cooling System Coolant Flow Rate:
9.500 gallons per minute
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
12.800 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.790 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
3.290 inches
MRC:
The range of complete cyclic changes,per unit of time,for which an item is rated.AFGQ
Frequency Range Rating:
+2.900/+3.100 gigahertz
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
OT-141/SPS-48E, transmitter group
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.15 and 2.00
MRC:
The amount of electrical energy that can be dissipated.AJDB
Power Rating:
3.500 megawatts peak and 50.000 kilowatts average
MRC:
The minimum and maximum values of the frequency range in which the voltage standing wave ratio is specified.AKNK
Voltage Standing Wave Ratio Frequency Range:
+2.900/+3.100 gigahertz and +2.600/+3.300 gigahertz
MRC:
Indicates the type of facility provided on the device for attaching to another item.AKRZ
Termination Type:
Waveguide flange
MRC:
The position in which the item is designed to operate.ARNH
Operating Position:
Horizontal or vertical
MRC:
The nominal outward force,per unit of area,of the coolant chamber.AWNJ
Coolant Chamber Pressure:
150.0 pounds per square inch gage
MRC:
The input temperature of the coolant.AWNL
Input Coolant Temp:
55.0 degrees celsius
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Forced liquid
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Flange without fins