Número de pieza 164.6185.5206

Inclosed Link Fuse

Precios y disponibilidad

Envíe este formulario para conocer los precios actuales y la disponibilidad de esta NSN.
Número de pieza:
Cantidad:
Dirección de correo electrónico:
Teléfono:
Referencia:
Compañía:
Nombre:

No compartimos ni vendemos su información a nadie.
Privacidad | Letra chica

All major credit cards accepted as well as gov. p-cards
Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
164.6185.5206
Desmilitarización:
Vigencia:
Unidad de medida:
NIIN:
016481510
NSN
Número de acciones nacionales:
5920-01-648-1510 5920016481510
TXT
Descripción:
Inclosed Link Fuse
INC
INC
Código de nombre del artículo:
00249
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Plug-in autofuse
MRC:
The element,compound,or mixture of which the terminal is fabricated.ABDM
Terminal Material:
Copper alloy
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
19.0 millimeters
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
19.7 millimeters
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
5.0 millimeters
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Plastic
MRC:
The maximum direct current,or root mean square current at rated frequency,that an item will carry continuously.AEBJ
Continuous Current Rating In Amps:
20.0
MRC:
A measurement taken at right angles to the length of the terminal,in distinction from thickness.AFWW
Unable To Decode:
5.2 millimeters
MRC:
A measurement of the smallest dimension of the terminal,in distinction from length or width.AFWY
Terminal Thickness:
3.8 millimeters
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
32.0 dc
MRC:
Indicates the type of over-current conditions that an item is designed to withstand indicated by the speed of circuit interruption.AFXF
Circuit Over-current Interruption Type:
Normal instantaneous
MRC:
The means in which the item signals the interruption of a circuit.AFXH
Interruption Indicator Method:
Visible element
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Rohs directive compliance
MRC:
The time elapsing before circuit interruption of an item operated at a specified percent of its normal current rating,expressed in seconds.CQPB
Circuit Over-current Interruption Delay Time In Seconds:
1800.0 135 pct of current rating
MRC:
The maximum rated current at which the item will interrupt or short circuit,expressed in amperes.CSQN
Short-circuit/interrupt Current Rating In Amps:
1000.0

Similar Inclosed Link Fuses

« Fuses, Arrestors, Absorbers and Protectors Catálogo
Comparar ahora»
Claro | Esconder