Número de pieza 152BL705P

Thermocoup Temperature Indicator

Precios y disponibilidad

Envíe este formulario para conocer los precios actuales y la disponibilidad de esta NSN.
Número de pieza:
Cantidad:
Dirección de correo electrónico:
Teléfono:
Referencia:
Compañía:
Nombre:

No compartimos ni vendemos su información a nadie.
Privacidad | Letra chica

All major credit cards accepted as well as gov. p-cards
Número de pieza
Desmilitarización
Vigencia
UOM
NIIN
Número de pieza:
152bl705p
Desmilitarización:
No
Vigencia:
Unidad de medida:
NIIN:
011143195

Información de la pieza
Scale calibration: 20 degrees c depth behind mounting flange: 2.782 inNom panel mounted body size: 1.812 inNom yellow arc from 560 degrees c to 630 degrees c red radial line at 680 degrees c critical point at 680 degc c dial marked exh temp flange height: 1.812 inNom scale name: temperature; instrument lamp: included nonluminous scale marking and color: major and minor graduation black electrical connection controlling agency: liquidometer

NSN
Número de acciones nacionales:
6685-01-114-3195 6685011143195
TXT
Descripción:
Thermocoup Temperature Indicator
INC
INC
Código de nombre del artículo:
03395
MRC:
An indication of the marking/s/ on the scale and the surface finish.ABFN
Scale Marking And Surface Finish:
Major graduation nonluminous and minor graduation nonluminous
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the circumference.ABMZ
Diameter:
2.000 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
3.000 inches
MRC:
A measurement taken at right angles to the length of a mounting flange,in distinction from thickness.ADMH
Mounting Flange Width:
0.218 inches
MRC:
An indication of the scale range.APSK
Scale Range:
+0.1/+850.0 degrees celsius single indicator single scale
MRC:
The number of electrical connections provided.ASKX
Electrical Connection Quantity:
1
MRC:
The identifying number assigned by the government agency or commercial organization controlling the electrical connection.ASKZ
Electrical Connection Identifying Number:
26E28-2A
MRC:
Indicates the type of pointer provided.ASST
Pointer Type:
Clock-hand single pointer
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
1 flange

Similar Thermocoup Temperature Indicators